TURBO WATER PIPE (for Outlet Side)
>>
Installation [03/2019 - 03/2020]
>>
Procedure
Installation [03/2019 - 03/2020]: Procedure
INSTALL NO. 2 TURBO WATER PIPE SUB-ASSEMBLY
Replace the O-ring (1).
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Position the No. 2 turbo water pipe sub-assembly.
Tighten down the T30 bolt.
Torque: 8.0 N.m (82 kgf/cm, 71 in.lbf)
INSTALL TURBOCHARGER SUB-ASSEMBLY
Refer to
INSTALLATION [03/2019 - 03/2020]