Odo/Trip Switch Malfunction [10/2022 - ]: Procedure
- READ VALUE USING GTS (ODO/TRIP CHANGE SWITCH)
- Using the GTS, read the Data List.
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note ODO/TRIP Change Switch ODO/TRIP switch (Trip switch) OFF or ON OFF: ODO/TRIP switch (trip switch) released
ON: ODO/TRIP switch (trip switch) pushed- Body Electrical > Combination Meter > Data List
Tester Display ODO/TRIP Change Switch OK
ODO/TRIP switch condition displayed on the GTS changes with the actual switch operation.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [10/2022 - ]
Result:
NG
See step 2
- Using the GTS, read the Data List.
- INSPECT TRIP SWITCH
Refer to INSPECTION [10/2022 - ]
Result
Proceed to OK NG Result:
NG
REPLACE TRIP SWITCH. Refer to REMOVAL [10/2022 - ]
Result:
OK
See step 3
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - TRIP SWITCH)
- Disconnect the G184 combination meter assembly connector.
- Disconnect the G177 trip switch connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G184-13 (ODO) - G177-5 (A/B) Always Below 1 Ω G184-26 (SW3) - G177-2 (E) Always Below 1 Ω G184-13 (ODO) or G177-5 (A/B) - Body ground Always 10 kΩ or higher G184-26 (SW3) or G177-2 (E) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [10/2022 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR