Hybrid System Indicator Malfunction [11/2015 -]: Procedure
- CHECK CAN COMMUNICATION SYSTEM
- Check if CAN communication DTCs are output.
Refer to DIAGNOSIS SYSTEM [11/2015 - 11/2017] , or refer to DIAGNOSIS SYSTEM [11/2017 - 12/2018] , or refer to DIAGNOSIS SYSTEM [12/2018 - 08/2019] , or refer to DIAGNOSIS SYSTEM [08/2019 - 07/2020] , or refer to DIAGNOSIS SYSTEM [07/2020 -]
Result
Result Proceed to CAN communication DTCs are not output. A CAN communication DTCs are output. B
Result:
B
GO TO CAN COMMUNICATION SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [11/2015 - 12/2018] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [12/2018 -]
Result:
A
See step 2
- Check if CAN communication DTCs are output.
- PERFORM ACTIVE TEST USING TECHSTREAM (HV SYSTEM INDICATOR)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Active Test.
- Perform the Active Test according to the display on the Techstream.
Body Electrical > Combination Meter > Active Test
Tester Display Measurement Item Control Range Diagnostic Note HV System Indicator Hybrid system indicator OFF, MIN, -50, 0, 100, 200, 300, 400, MAX - Body Electrical > Combination Meter > Active Test
Tester Display HV System Indicator OK
Hybrid system indicator indication is normal.
Result
Proceed to OK NG
Result:
NG
REPLACE COMBINATION METER ASSEMBLY (METER CIRCUIT PLATE). Refer to DISASSEMBLY [11/2015 -]
Result:
OK
See step 3
- READ VALUE USING TECHSTREAM (HV SYSTEM INDICATOR)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note HV System Indicator Hybrid system indicator value Min.: -512%, Max.: 511% -512 to 511% - Body Electrical > Combination Meter > Data List
Tester Display HV System Indicator OK
Hybrid system indicator value displayed on the Techstream is almost the same as the hybrid system indicator indication.
Result
Proceed to OK NG
Result:
NG
GO TO HYBRID CONTROL SYSTEM
for Nickel Metal Hydride Battery: Refer to HOW TO PROCEED WITH TROUBLESHOOTING [11/2015 -]
for Lithium-ion Battery: Refer to HOW TO PROCEED WITH TROUBLESHOOTING [11/2015 -]
Result:
OK
See step 4
- REPLACE COMBINATION METER ASSEMBLY (METER CIRCUIT PLATE)
- Replace the combination meter assembly (meter circuit plate) with a new or known good one.
Refer to DISASSEMBLY [11/2015 -]
OK
The operation of the hybrid system indicator returns to normal.
Result
Proceed to OK NG
Result:
OK
END
Result:
NG
REPLACE HYBRID VEHICLE CONTROL ECU. Refer to REMOVAL [11/2015 - 12/2018] , or refer to REMOVAL [12/2018 - 08/2019] , or refer to REMOVAL [08/2019 - 07/2020] , or refer to REMOVAL [07/2020 -]
- Replace the combination meter assembly (meter circuit plate) with a new or known good one.