Fuel Lid Opener System Operation Message Display Malfunction [07/2020 -]: Procedure
- INSPECT COMBINATION METER ASSEMBLY (METER CIRCUIT PLATE) (OUTPUT VOLTAGE)
*a Front view of wire harness connector
(to ECM)- Disconnect the A40 ECM connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition A40-24 (LSTM) - Body ground Power switch off 11 to 14 V Result
Proceed to OK NG
Result:
NG
See step 3
Result:
OK
See step 2
- INSPECT COMBINATION METER ASSEMBLY (METER CIRCUIT PLATE) (INPUT WAVEFORM)
*a Component with harness connected
(Combination Meter Assembly (Meter Circuit Plate))- Check the input waveform.
- Connect the A40 ECM connector.
- Remove the combination meter assembly (meter circuit plate) with the connector(s) still connected.
- Operate the fuel lid opener switch.
- Check the signal waveform according to the condition(s) in the table below.
- Waveform 1:
Item Condition Tester Connection F6-37 (LST1) - Body ground Tool setting 5 V/DIV., 20 ms./DIV. Condition The following message (interrupt display) being displayed on the multi-information display: - Please Wait Now Opening
HINT:
This waveform is output when the internal pressure of the fuel tank is higher than the ambient pressure when the fuel lid opener switch is operated.
- Waveform 2:
Item Condition Tester Connection F6-37 (LST1) - Body ground Tool setting 5 V/DIV., 20 ms./DIV. Condition The following message (interrupt display) being displayed on the multi-information display: - Refuel Ready
- Waveform 3:
Item Condition Tester Connection F6-37 (LST1) - Body ground Tool setting 5 V/DIV., 20 ms./DIV. Condition The following message (interrupt display) being displayed on the multi-information display: - Close Fuel Lid
HINT:
This waveform is output when the fuel lid opener switch is operated if the fuel lid is open and any of the following conditions are met:
- The vehicle has been driven for 1 km (0.6 mile) or more at a speed of 50 km/h (31 mph) or more.
- 30 minutes or more have elapsed since the fuel lid opener switch was operated.
OK
All of the waveforms are output normally.
- Waveform 1:
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY (METER CIRCUIT PLATE). Refer to DISASSEMBLY [11/2015 -]
Result:
NG
REPLACE ECM. Refer to REMOVAL [07/2020 -]
- Check the input waveform.
- CHECK HARNESS AND CONNECTOR (ECM - COMBINATION METER ASSEMBLY (METER CIRCUIT PLATE))
- Disconnect the F6 combination meter assembly (meter circuit plate) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A40-24 (LSTM) - F6-37 (LST1) Always Below 1 Ω A40-24 (LSTM) or F6-37 (LST1) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY (METER CIRCUIT PLATE). Refer to DISASSEMBLY [11/2015 -]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR