Entire Combination Meter does not Operate [11/2015 -]: Procedure
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Disconnect the F6 combination meter assembly (meter circuit plate) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition F6-28 (ES) - Body ground Always Below 1 Ω F6-40 (EP) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition F6-21 (IG+) - Body ground Power switch off Below 1 V Power switch on (IG) 11 to 14 V F6-22 (B) - Body ground Power switch off 11 to 14 V Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY (METER CIRCUIT PLATE). Refer to DISASSEMBLY [11/2015 -]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR