Odo/Trip Switch Malfunction [12/2023 - ]: Procedure
- READ VALUE USING GTS (ODO/TRIP CHANGE SW)
- Using the GTS, read the Data List.
Refer to DATA LIST / ACTIVE TEST [12/2023 - ]
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note ODO/TRIP Change Switch ODO/TRIP switch (Trip switch) OFF/ON OFF: Switch released
ON: Switch pushed- Body Electrical > Combination Meter > Data List
Tester Display ODO/TRIP Change Switch OK
ODO/TRIP switch condition displayed on the GTS changes with the actual switch operation.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [12/2023 - ]
Result:
NG
See step 2
- Using the GTS, read the Data List.
- INSPECT TRIP SWITCH
Refer to INSPECTION [11/2020 - ]
Result
Proceed to OK NG Result:
NG
REPLACE TRIP SWITCH. Refer to REMOVAL [11/2020 - ]
Result:
OK
See step 3
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - TRIP SWITCH)
- Disconnect the D43*1 or D200*2 combination meter assembly connector.
- *1: w/ Front LiDAR Sensor
- *2: w/o Front LiDAR Sensor
- Disconnect the D7 trip switch connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
W/ FRONT LIDAR SENSORTester Connection Condition Specified Condition D43-13 (ODO) - D7-9 (A/B) Always Below 1 Ω D43-28 (SW3) - D7-1 (E) Always Below 1 Ω D43-13 (ODO) or D7-9 (A/B) - Body ground Always 10 kΩ or higher D43-28 (SW3) or D7-1 (E) - Body ground Always 10 kΩ or higher W/O FRONT LIDAR SENSORTester Connection Condition Specified Condition D200-13 (ODO) - D7-9 (A/B) Always Below 1 Ω D200-26 (SW3) - D7-1 (E) Always Below 1 Ω D200-13 (ODO) or D7-9 (A/B) - Body ground Always 10 kΩ or higher D200-26 (SW3) or D7-1 (E) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [12/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- Disconnect the D43*1 or D200*2 combination meter assembly connector.