Hazard Warning Switch Circuit [11/2020 - 11/2021]: Procedure
- READ VALUE USING GTS
- Read the Data List according to the display on the GTS.
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Hazard Flasher Switch Hazard warning signal switch signal OFF or ON OFF: Hazard warning signal switch off
ON: Hazard warning signal switch on- Body Electrical > Combination Meter > Data List
Tester Display Hazard Flasher Switch OK
Normal conditions listed above are displayed.
Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [11/2020 - 12/2023]
Result:
NG
See step 2
- Read the Data List according to the display on the GTS.
- INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY
Refer to INSPECTION [11/2020 - 11/2021]
Result
Proceed to OK NG Result:
NG
REPLACE HAZARD WARNING SIGNAL SWITCH ASSEMBLY. Refer to REMOVAL [11/2020 - 12/2022]
Result:
OK
See step 3
- CHECK HARNESS AND CONNECTOR (HAZARD WARNING SIGNAL SWITCH ASSEMBLY - COMBINATION METER ASSEMBLY AND BODY GROUND)
- *1: w/ Advanced Driver
- *2: w/o Advanced Driver
- Disconnect the D101*1 or D99*2 hazard warning signal switch assembly connector.
- Disconnect the D44*1 or D42*2 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
W/ ADVANCED DRIVERTester Connection Condition Specified Condition D101-6 (TB) - D44-12 (HAZ) Always Below 1 Ω D101-6 (TB) or D44-12 (HAZ) - Body ground Always 10 kΩ or higher D101-3 (E) - Body ground Always Below 1 Ω W/O ADVANCED DRIVERTester Connection Condition Specified Condition D99-5 (TB) - D42-2 (HAZ) Always Below 1 Ω D99-5 (TB) or D42-2 (HAZ) - Body ground Always 10 kΩ or higher D99-4 (E) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [11/2020 - 11/2021]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR