LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2021 >> Mirai Limited >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Testing and Diagnosis >> Hybrid Control System - Diagnostic Codes (18 Of 18) & Circuit Tests (1 Of 3) >> Hybrid Control System >> DTC P33B9-9F: Motor/Generator Shutdown Signal (Hybrid/EV Side) Stuck Off [11/2020 - ] >> Description

DTC P33B9-9F: Motor/Generator Shutdown Signal (Hybrid/EV Side) Stuck Off [11/2020 - ]: Description

Refer to the description for DTC P321E-9F.

Refer to DESCRIPTION  Refer to DESCRIPTION  Refer to DESCRIPTION 

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P33B9-9F Motor/Generator Shutdown Signal (Hybrid/EV Side) Stuck Off When the EV gate shutdown function check is performed (when the ignition switch is turned from to ON (READY) to off) and checked at the motor generator control ECU (MG ECU), the shutdown signals sent by the main CPU and sub CPU of the EV control ECU do not match.
(1 trip detection logic)
EV control ECU Master Warning:
Comes on
EV A
RELATED DATA LIST

DTC No. Data List
P33B9-9F -