DTC P338F-00: FC Air Compressor Inverter Overcurrent (System Performance) [11/2020 - 12/2022]: Procedure
- CHECK DTC OUTPUT (EV)
Pre-procedure1
- None.
- Check for DTCs.
Powertrain > EV > Trouble Codes
Result
Result Proceed to P338F-00 only is output, or DTCs except the ones in the tables below are also output. A Any of the following DTCs including pending DTCs are also output. B Malfunction Content Relevant DTC Microcomputer malfunction P0A1B-49 Drive Motor "A" Control Module Internal Electronic Failure P0606-47 Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure P0A1B-1F Drive Motor "A" Control Module Circuit Intermittent P1D8F-47 FC Air Compressor Motor Control Module Watchdog/Safety MCU Failure P1D8F-49 FC Air Compressor Motor Control Module Internal Electronic Failure P1D04-00 FC Air Compressor Motor Control Module A/D Processing Performance Power source circuit malfunction P06D6-1C Sensor Reference Voltage "F" Circuit/Open Circuit Voltage Out of Range P06E6-1C Sensor Power Supply "C" Circuit/Open Circuit Voltage Out of Range Communication system malfunction P3123-87 Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message U0111-87 Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message P1E3B-87 Communication Error from FC Air Compressor Motor to Drive Motor "A" Missing Message Sensor and actuator circuit malfunction P0AD9-11 Hybrid/EV Battery Positive Contactor Circuit Short to Ground P0AD9-15 Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open P0ADD-11 Hybrid/EV Battery Negative Contactor Circuit Short to Ground P0ADD-15 Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open P0ABF-00 Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance P0D2D-16 Drive Motor "A" Inverter Voltage Sensor "A" Circuit Voltage Below Threshold P0D2D-17 Drive Motor "A" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold System malfunction P0D2D-1C Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range P1C83-49 High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction P0E31-1C Boosting Converter Voltage Sensor "A" Voltage Out of Range P3004-49 High Voltage Power Resource Circuit Short during Pre-Charge P1C2D-62 Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure P0A1F-94 Hybrid/EV Battery Energy Control Module Unexpected Operation P1CB6-9E Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On P0CA3-00 DC/DC Converter Step Up Voltage Performance HINT:
- P338F-00 may be output as a result of the malfunction indicated by the DTCs above.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
- P338F-00 may be output as a result of the malfunction indicated by the DTCs above.
Post-procedure1
- Turn the ignition switch off.
Result:
B
GO TO DTC CHART (EV CONTROL SYSTEM). Refer To DIAGNOSTIC TROUBLE CODE CHART [11/2020 - 12/2022]
Result:
A
See step 2
- CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Refer to PROCEDURE - Step 2
Result
Result Proceed to OK A NG (The connector is not connected securely.) B NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C Result:
B
CONNECT SECURELY
Result:
C
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
A
See step 3
- CHECK FC AIR COMPRESSOR RESOLVER CIRCUIT
Refer to FC Air Compressor Resolver Circuit [11/2020 - 12/2022]
Result
Proceed to NEXT Result:
NEXT
See step 4
- CHECK FC AIR COMPRESSOR HIGH-VOLTAGE CIRCUIT
Refer to FC Air Compressor High-voltage Circuit [11/2020 - 12/2022]
Result
Proceed to NEXT Result:
NEXT
See step 5
- CHECK INVERTER LOW-VOLTAGE CIRCUIT
Refer to Inverter Low-voltage Circuit [11/2020 - 12/2022]
Result
Proceed to NEXT Result:
NEXT
REPLACE INVERTER WITH CONVERTER ASSEMBLY. Refer to REMOVAL [11/2020 - 11/2021] , or refer to REMOVAL [11/2021 - 12/2022]