DTC C1020-14: Ignition Switch On/Start Position Circuit Short to Ground or Open [12/2023 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (IG1 TERMINAL)
- Make sure that there is no looseness at the locking part and the connecting part of the connector.
OK
The connector is securely connected.
Pre-procedure1
- Disconnect the A6 No. 2 skid control ECU (brake actuator assembly) connector.
- Check both the connector case and the terminals for deformation and corrosion.
OK
No deformation or corrosion.
Pre-procedure2
- Turn the ignition switch to ON.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition Result A6-45 (IG1) - Body ground Ignition switch ON 11 to 14 V V Result
Proceed to OK NG
Post-procedure1
- None
Result:
OK
REPLACE BRAKE ACTUATOR ASSEMBLY. Refer to REMOVAL [12/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- Make sure that there is no looseness at the locking part and the connecting part of the connector.