Inspection [11/2020 - ]: Procedure
- INSPECT FRONT SEAT CUSHION HEATER ASSEMBLY LH
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Front Seat Cushion Heater Assembly LH)Standard Resistance
Tester Connection Condition Specified Condition Result L35-1 - A-1 Always 20°C (68°F) Below 1 Ω Ω L35-1 - A-2 Always 20°C (68°F) 3.20 to 3.83 Ω Ω L35-2 - L35-6 Always 20°C (68°F) Below 1 Ω Ω L35-2 - A-2 Always 20°C (68°F) Below 1 Ω Ω L35-4 - L35-5 Always 20°C (68°F) 11.94 to 12.24 kΩ kΩ A-1 - A-2 Always 20°C (68°F) 3.26 to 3.90 Ω Ω If the result is not as specified, replace the front seat cushion heater assembly LH.
- Measure the resistance according to the value(s) in the table below.
- INSPECT FRONT SEAT CUSHION HEATER ASSEMBLY RH
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Front Seat Cushion Heater Assembly RH)Standard Resistance
Tester Connection Condition Specified Condition Result L10-1 - A-1 Always 20°C (68°F) Below 1 Ω Ω L10-1 - A-2 Always 20°C (68°F) 3.20 to 3.83 Ω Ω L10-2 - L10-6 Always 20°C (68°F) Below 1 Ω Ω L10-2 - A-2 Always 20°C (68°F) Below 1 Ω Ω L10-4 - L10-5 Always 20°C (68°F) 11.94 to 12.24 kΩ kΩ A-1 - A-2 Always 20°C (68°F) 3.26 to 3.90 Ω Ω If the result is not as specified, replace the front seat cushion heater assembly RH.
- Measure the resistance according to the value(s) in the table below.