Meter Illumination is Always Dark [08/2015 - ]: Procedure
- CHECK CAN COMMUNICATION SYSTEM
- Check for DTCs (Refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2015 - ]
).RESULT
Result Proceed to DTC is not output A CAN communication system DTC is output B Lighting system DTC (B1244) is output C
Result:
B
Go to CAN COMMUNICATION SYSTEM
(Refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2015 - ] )
Result:
C
Go to LIGHTING SYSTEM
(Refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2015 - ] )
Result:
A
See step 2
- Check for DTCs (Refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2015 - ]
).
- PERFORM ACTIVE TEST USING TECHSTREAM (DIMMER SWITCH)
- Operate the Techstream according to the display and select Active Test (Refer to DATA LIST / ACTIVE TEST [08/2015 - ]
).MAIN BODY
Tester Display Test Part Control Range Diagnostic Note Dimmer Signal Illumination dimming operation ON or OFF - OK
Meter illumination is dimmed when the dimmer switch is ON.
HINT:
Refer to the sensitivity setting in the customization table of the automatic light control system (Refer to CUSTOMIZE PARAMETERS [08/2015 - ] ).
Result:
OK
CHECK LIGHTING SETTING
(Refer to CUSTOMIZE PARAMETERS [08/2015 - ] )
Result:
NG
See step 3
- Operate the Techstream according to the display and select Active Test (Refer to DATA LIST / ACTIVE TEST [08/2015 - ]
).
- REPLACE COMBINATION METER ASSEMBLY
- Temporarily replace the combination meter with a new one (Refer to REMOVAL [08/2015 - ] ).
Result:
NEXT
See step 4
- CHECK COMBINATION METER ASSEMBLY
- Check that the operation of the combination meter returns to normal (Refer to REMOVAL [08/2015 - ]
).
OK
Operation of combination meter returns to normal.
Result:
OK
END (COMBINATION METER IS DEFECTIVE)
Result:
NG
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)
(Refer to REMOVAL [08/2015 - ] )
- Check that the operation of the combination meter returns to normal (Refer to REMOVAL [08/2015 - ]
).