Entire Combination Meter does not Operate [08/2015 - ]: Procedure
- INSPECT FUSE (METER, MPX-B NO. 2)
- Remove the METER and MPX-B NO. 2 fuses from the engine room relay block.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition METER fuse Always Below 1 Ω MPX-B NO. 2 fuse
Result:
NG
REPLACE FUSE
Result:
OK
See step 2
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
- Disconnect the E99 Combination meter assembly connector.
- Measure the resistance and voltage according to the value(s) in the tables below.
Standard Resistance
Tester Connection Condition Specified Condition E99-20 (ET) - Body ground Always Below 1 Ω Standard Voltage
Tester Connection Switch Condition Specified Condition E99-21 (B) - Body ground Always 11 to 14 V E99-22 (IG+) - Body ground Engine switch on (IG) TEXT IN ILLUSTRATION*a Component without harness connected
(Combination Meter Assembly)
Result:
OK
REPLACE COMBINATION METER ASSEMBLY
(Refer to REMOVAL [08/2015 - ] )
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR