Home >> Toyota >> 2021 >> Highlander Platinum, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 55 (Engine Control System (T24A-FTS) - Diagnostic Codes (07 Of 11)) >> SFI System >> DTC P062F-44: Internal Control Module EEPROM Data Memory Failure [11/2023 - ] >> Typical Malfunction Thresholds

Typical Malfunction Thresholds

WARNING: This page is about a different car, the 2025 Toyota Highlander, 2024 Toyota Highlander, and 2023 Toyota Highlander. However, it is still accessible from the selected car via links, so may be relevant.
CASE 1

The following condition is met 2 data or more
One of the following conditions (a), (b) or (c) is met More than 3 times
(a) EEPROM access error Occurred
(b) Permanent Fault Code Not stored
(c) Permanent Fault Code Not equal to commanded Fault Code
CASE 2

The following condition is met 2 data or more
Either of the following conditions (a) or (b) is met More than 3 times
(a) EEPROM access error Occurred
(b) Permanent Fault Code Stored
CASE 3

Either of the following conditions is met 1 or 2
1. The following condition is met 2 data or more
EEPROM access error (more than 3 times) Occurred
2. Permanent Fault Code data (more than 10 times) Mismatch