Weak Blower Output [06/2017 - 10/2020]: Procedure
- CHECK AIR CONDITIONING SYSTEM
- Operate the blower switch with the following conditions met and check that the airflow volume changes.
Blower Speed Condition LO → HI - Temperature setting: MAX COLD
- Air outlet mode: FACE
- A/C switch: Off
OK
Airflow volume increases.
Result
Proceed to OK NG
Result:
NG
GO TO OTHER DIAGNOSIS PROCEDURE (Blower Motor Circuit). Refer to Blower Motor Circuit [03/2017 - 10/2020]
Result:
OK
See step 2
- Operate the blower switch with the following conditions met and check that the airflow volume changes.
- CHECK ECO MODE CONTROL OPERATION
- Check that ECO mode control is disabled (ECO mode indicator is not illuminated).
- Operate the ECO switch assembly (electric parking brake switch assembly) and check that the ECO mode indicator illuminates and the blower speed is reduced.
HINT:
- When ECO mode control is operating, the air conditioning amplifier assembly controls the air conditioning system to enhance fuel efficiency. Therefore, explain to the customer that, when ECO mode control is operating, the blower speed will be reduced.
Control Outline Blower Control When the air conditioning system is in AUTO mode, the blower speed will be reduced to a certain speed. Additionally, if warm-up control is operating, the blower speed will be further reduced. Air Inlet Control If the ambient temperature is a certain value or more, the air inlet mode will be changed to recirculation mode. - In some situations, ECO mode control may not operate even though it is enabled.
- When ECO mode control is operating, the air conditioning amplifier assembly controls the air conditioning system to enhance fuel efficiency. Therefore, explain to the customer that, when ECO mode control is operating, the blower speed will be reduced.
- Operate the ECO switch assembly (electric parking brake switch assembly) and check that the ECO mode indicator turns off and the blower speed returns to normal.
OK
When the ECO switch assembly (electric parking brake switch assembly) is operated, ECO mode control is enabled/disabled and the blower speed is controlled.
Result
Proceed to OK NG
Result:
NG
GO TO ECO Switch Circuit. Refer to ECO Switch Circuit [06/2017 - ]
Result:
OK
See step 3
- CHECK CLEAN AIR FILTER
- Visually check the clean air filter.
Refer to REMOVAL [03/2017 - ]
OK
The clean air filter is not dirty or clogged.
Result
Proceed to OK NG
Result:
NG
REPLACE CLEAN AIR FILTER. Refer to REMOVAL [03/2017 - ]
Result:
OK
See step 4
- Visually check the clean air filter.
- CHECK NO. 1 COOLER THERMISTOR
- Check the installation condition of the No. 1 cooler thermistor.
OK
The No. 1 cooler thermistor is installed correctly.
Result
Proceed to OK NG
Result:
NG
INSTALL NO. 1 COOLER THERMISTOR CORRECTLY. Refer to INSTALLATION [03/2017 - ]
Result:
OK
See step 5
- Check the installation condition of the No. 1 cooler thermistor.
- CHECK ASPIRATOR
- Check the installation condition of the aspirator.
OK
The aspirator is installed correctly.
Result
Proceed to OK NG
Result:
OK
REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY. Refer to REMOVAL [06/2017 - 09/2019] , or refer to REMOVAL [09/2019 - 03/2020] , or refer to REMOVAL [03/2020 - 10/2020]
Result:
NG
INSTALL ASPIRATOR CORRECTLY. Refer to REASSEMBLY [06/2017 - 10/2020]
- Check the installation condition of the aspirator.