Inspection [06/2017 - ]: Procedure
- INSPECT FRONT SEATBACK HEATER ASSEMBLY LH
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Front Seatback Heater Assembly LH)Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 Seat heater temperature 23°C (73°F) 4.2 to 5.2 Ω If the result is not as specified, replace the front seatback heater assembly LH.
- Measure the resistance according to the value(s) in the table below.
- INSPECT FRONT SEATBACK HEATER ASSEMBLY RH
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Front Seatback Heater Assembly RH)Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 Seat heater temperature 23°C (73°F) 4.2 to 5.2 Ω If the result is not as specified, replace the front seatback heater assembly RH.
- Measure the resistance according to the value(s) in the table below.