Weak Blower Output [03/2017 - 06/2017]: Procedure
- CHECK AIR CONDITIONING SYSTEM
- Operate the blower switch with the following conditions met and check that the airflow volume changes.
Blower Speed Condition LO → HI - Temperature setting: MAX COLD
- Air outlet mode: FACE
- A/C switch: Off
OK
Airflow volume increases.
Result
Proceed to OK NG
Result:
NG
GO TO OTHER DIAGNOSIS PROCEDURE (Blower Motor Circuit). Refer to Blower Motor Circuit [03/2017 - 10/2020]
Result:
OK
See step 2
- Operate the blower switch with the following conditions met and check that the airflow volume changes.
- CHECK CLEAN AIR FILTER
- Visually check the clean air filter.
Refer to REMOVAL [03/2017 - ]
OK
The clean air filter is not dirty or clogged.
Result
Proceed to OK NG
Result:
NG
REPLACE CLEAN AIR FILTER. Refer to REMOVAL [03/2017 - ]
Result:
OK
See step 3
- Visually check the clean air filter.
- CHECK NO. 1 COOLER THERMISTOR
- Check the installation condition of the No. 1 cooler thermistor.
OK
The No. 1 cooler thermistor is installed correctly.
Result
Proceed to OK NG
Result:
NG
INSTALL NO. 1 COOLER THERMISTOR CORRECTLY. Refer to INSTALLATION [03/2017 - ]
Result:
OK
See step 4
- Check the installation condition of the No. 1 cooler thermistor.
- CHECK ASPIRATOR
- Check the installation condition of the aspirator.
OK
The aspirator is installed correctly.
Result
Proceed to OK NG
Result:
OK
REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY. Refer to REMOVAL [03/2017 - 06/2017]
Result:
NG
INSTALL ASPIRATOR CORRECTLY. Refer to REASSEMBLY [03/2017 - 06/2017]
- Check the installation condition of the aspirator.