Indicator does not Illuminate [10/2020 - ]: Procedure
- CHECK AIR CONDITIONING CONTROL ASSEMBLY
- Check that the switch indicators on the air conditioning control assembly illuminate immediately after the engine is started.
OK
All switch indicators illuminate.
Result
Result OK NG
Result:
NG
REPLACE AIR CONDITIONING CONTROL ASSEMBLY. Refer to REMOVAL [10/2020 - ]
Result:
OK
See step 2
- Check that the switch indicators on the air conditioning control assembly illuminate immediately after the engine is started.
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Ambient Temp Sensor Thermistor assembly Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)Actual ambient temperature displayed - Body Electrical > Air Conditioner > Data List
Tester Display Ambient Temp Sensor OK
The value displayed is 0°C (32°F) or higher.
Result
Proceed to OK NG
Result:
OK
INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET. Refer to ON-VEHICLE INSPECTION [03/2017 - ]
Result:
NG
GO TO OTHER DIAGNOSIS PROCEDURE (Ambient Temperature Display System). Refer to Ambient Temperature Display System [03/2017 - ]