Front Window Fogging [10/2020 - ]: Procedure
- PERFORM REFRIGERANT SHORTAGE CHECK
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
Body Electrical > Air Conditioner > Utility
Tester Display Refrigerant Gas Volume Check - Check that the following conditions are met and perform the refrigerant shortage check according to the display on the Techstream.MEASUREMENT CONDITION:
Item Condition A/C switch On Ambient temperature* 0 to 49°C (32 to 120°F) Blower speed HI *: If the ambient temperature is not within the range shown, do not perform this check.
Result
Result Amount of Refrigerant Refrigerant correct Correct Refrigerant shortage Insufficient OK
"Refrigerant correct" is displayed on Techstream.
Result
Proceed to OK NG
Result:
NG
CHARGE SYSTEM WITH REFRIGERANT. Refer to REPLACEMENT [03/2017 - ]
Result:
OK
See step 2
- CHECK OPERATION
- Press the front defroster switch on the air conditioning control assembly and check that the air outlet mode changes to DEF mode.
OK
The air outlet mode changes to DEF mode.
Result
Proceed to OK NG
Result:
OK
INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET. Refer to ON-VEHICLE INSPECTION [03/2017 - ]
Result:
NG
GO TO DTC B1443. Refer to DTC B1443: Air Outlet Damper Control Servo Motor Circuit [03/2017 - ]
- Press the front defroster switch on the air conditioning control assembly and check that the air outlet mode changes to DEF mode.