Entire Combination Meter does not Operate [03/2017 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Disconnect the K21 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition K21-21 (ES) - Body ground Always Below 1 Ω K21-2 (EP) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition K21-39 (IG+) - Body ground Ignition switch off Below 1 V Ignition switch ON 11 to 14 V K21-40 (B) - Body ground Ignition switch off 11 to 14 V Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [03/2017 - 06/2017] , or refer to REMOVAL [06/2017 - 10/2020] , or refer to REMOVAL [10/2020 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR