Inside Handle Illumination Light Circuit [06/2017 - ]: Procedure
- PERFORM ACTIVE TEST USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Active Test.
- Perform the Active Test according to the display on the Techstream.
Body Electrical > Main Body > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Interior Illumination Light2 Inside handle illumination light (No. 1 interior illumination light assembly) OFF or ON Preconditions for using the Active Test to check dimmer controlled illumination: - Ignition switch ON
- Shift lever is in any position other than P
Body Electrical > Main Body > Active Test
Tester Display Interior Illumination Light2 OK
Inside handle illumination lights come on.
Result
Result Proceed to OK A NG (Inside handle illumination light LH does not come on) B NG (Inside handle illumination light RH does not come on) C NG (Inside handle illumination light LH and RH do not come on) D
Result:
A
USE SIMULATION METHOD TO CHECK. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [06/2017 - 08/2018] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2018 - 09/2019] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [09/2019 - 03/2020] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [03/2020 - 10/2020] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [10/2020 - 08/2021] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2021 - ]
Result:
C
See step 5
Result:
D
See step 8
Result:
B
See step 2
- INSPECT NO. 1 INTERIOR ILLUMINATION LIGHT ASSEMBLY LH
- Remove the inside handle illumination light LH (No. 1 interior illumination light assembly LH).
Refer to REMOVAL [06/2017 - 09/2019] , or refer to REMOVAL [09/2019 - ]
- Inspect the inside handle illumination light LH (No. 1 interior illumination light assembly LH).
Refer to INSPECTION [06/2017 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE INSIDE HANDLE ILLUMINATION LIGHT LH (NO. 1 INTERIOR ILLUMINATION LIGHT ASSEMBLY LH). Refer to REMOVAL [06/2017 - 09/2019] , or refer to REMOVAL [09/2019 - ]
Result:
OK
See step 3
- Remove the inside handle illumination light LH (No. 1 interior illumination light assembly LH).
- CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - NO. 1 INTERIOR ILLUMINATION LIGHT ASSEMBLY LH)
- Disconnect the 3B instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3B-26 - O14-2 (+) Always Below 1 Ω Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- CHECK HARNESS AND CONNECTOR (NO. 1 INTERIOR ILLUMINATION LIGHT ASSEMBLY LH - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))
- Disconnect the K53 main body ECU (multiplex network body ECU) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition O14-1 (-) - K53-21 (LED2) Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
USE SIMULATION METHOD TO CHECK. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [06/2017 - 08/2018] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2018 - 09/2019] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [09/2019 - 03/2020] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [03/2020 - 10/2020] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [10/2020 - 08/2021] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2021 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- INSPECT NO. 1 INTERIOR ILLUMINATION LIGHT ASSEMBLY RH
- Remove the inside handle illumination light RH (No. 1 interior illumination light assembly RH).
Refer to REMOVAL [06/2017 - 09/2019] , or refer to REMOVAL [09/2019 - ]
- Inspect the inside handle illumination light RH (No. 1 interior illumination light assembly RH).
Refer to INSPECTION [06/2017 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE INSIDE HANDLE ILLUMINATION LIGHT RH (NO. 1 INTERIOR ILLUMINATION LIGHT ASSEMBLY RH). Refer to REMOVAL [06/2017 - 09/2019] , or refer to REMOVAL [09/2019 - ]
Result:
OK
See step 6
- Remove the inside handle illumination light RH (No. 1 interior illumination light assembly RH).
- CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - NO. 1 INTERIOR ILLUMINATION LIGHT ASSEMBLY RH)
- Disconnect the 3B instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3B-26 - N14-2 (+) Always Below 1 Ω Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 7
- CHECK HARNESS AND CONNECTOR (NO. 1 INTERIOR ILLUMINATION LIGHT ASSEMBLY RH - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))
- Disconnect the K53 main body ECU (multiplex network body ECU) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition N14-1 (-) - K53-21 (LED2) Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
USE SIMULATION METHOD TO CHECK. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [06/2017 - 08/2018] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2018 - 09/2019] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [09/2019 - 03/2020] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [03/2020 - 10/2020] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [10/2020 - 08/2021] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2021 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (POWER SOURCE - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Disconnect the 3F instrument panel junction block assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 3F-1 - Body ground Always 11 to 14 V Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 9
- CHECK INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
*a Component without harness connected
(Instrument Panel Junction Block Assembly)- - - Disconnect the 3B instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3B-26 - 3F-1 Always Below 1 Ω Result
Proceed to OK NG
Result:
NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [06/2017 - 10/2020] , or refer to REMOVAL [10/2020 - ]
Result:
OK
See step 10
- CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - NO. 1 INTERIOR ILLUMINATION LIGHT ASSEMBLY)
- Disconnect the O14 inside handle illumination light LH (No. 1 interior illumination light assembly LH) connector.
- Disconnect the N14 inside handle illumination light RH (No. 1 interior illumination light assembly RH) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3B-26 - O14-2 (+) Always Below 1 Ω 3B-26 - N14-2 (+) Always Below 1 Ω 3B-26, O14-2 (+) or N14-2 (+) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 11
- CHECK HARNESS AND CONNECTOR (NO. 1 INTERIOR ILLUMINATION LIGHT ASSEMBLY - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))
- Disconnect the K53 main body ECU (multiplex network body ECU) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition O14-1 (-) - K53-21 (LED2) Always Below 1 Ω N14-1 (-) - K53-21 (LED2) Always Below 1 Ω O14-1 (-), N14-1 (-) or K53-21 (LED2) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [06/2017 - 10/2020] , or refer to REMOVAL [10/2020 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR