Blind Spot Monitor Sensor Communication Stop Mode [03/2017 - ]: Procedure
- CHECK FOR OPEN IN CAN BUS LINES (BLIND SPOT MONITOR SENSOR RH BRANCH LINE)
- Disconnect the cable from the negative (-) battery terminal.
- Disconnect the W5 blind spot monitor sensor RH connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition W5-2 (CA1P) - W5-7 (CA1N) Cable disconnected from negative (-) battery terminal 54 to 69 Ω *a Front view of wire harness connector
(to Blind Spot Monitor Sensor RH)Result
Result OK NG
Result:
NG
REPAIR OR REPLACE CAN BRANCH LINES OR CONNECTOR (BLIND SPOT MONITOR SENSOR RH)
Result:
OK
See step 2
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition W5-10 (BRGD) - Body ground Cable disconnected from negative (-) battery terminal Below 1 Ω *a Front view of wire harness connector
(to Blind Spot Monitor Sensor RH) - Reconnect the cable to the negative (-) battery terminal.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition W5-5 (BRB) - Body ground Ignition switch ON 11 to 14 V Result
Result OK NG
Result:
OK
REPLACE BLIND SPOT MONITOR SENSOR RH. Refer to REMOVAL [03/2017 - 06/2017] , or refer to REMOVAL [06/2017 - 10/2020] , or refer to REMOVAL [10/2020 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.