Removal [05/2018 - 12/2021]: Procedure
- RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM (for HFC-134a (R134a))
Refer to PROCEDURE - Step 1
- RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM (for HFO-1234yf (R1234yf))
Refer to PROCEDURE - Step 1
- REMOVE NO. 1 ENGINE UNDER COVER
Refer to PROCEDURE - Step 7 [10/2017 - 08/2020] , or refer to PROCEDURE - Step 7 [08/2020 - 12/2021]
- REMOVE FAN AND GENERATOR V BELT
Refer to REMOVAL [02/2017 - ]
- DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY
- Disconnect the connector.
- Remove the bolt to disconnect the discharge hose sub-assembly from the compressor with pulley assembly.
- Remove the O-ring from the discharge hose sub-assembly.NOTE:
Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering them.
- Disconnect the connector.
- DISCONNECT SUCTION HOSE SUB-ASSEMBLY
- REMOVE COMPRESSOR WITH PULLEY ASSEMBLY