Installation [09/2019 - 08/2020]: Procedure
- INSTALL STARTER ASSEMBLY
- Install the starter assembly to the cylinder block sub-assembly with the 2 bolts.
Torque: 46 N*m (469 kgf*cm, 34 ft.*lbf)
- Connect the wire harness to the terminal 30 with the nut.
Torque: 9.8 N*m (100 kgf*cm, 87 in.*lbf)
- Close the terminal cap.
- Connect the starter assembly connector.
- Install the starter assembly to the cylinder block sub-assembly with the 2 bolts.
- CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Refer to PROCEDURE - Step 2
NOTE:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Refer to INITIALIZATION [09/2019 - 08/2020]
- INSTALL NO. 1 ENGINE UNDER COVER
Refer to PROCEDURE - Step 61