Front Fog Light Circuit [08/2020 - 12/2021]: Procedure
- CHECK OPERATION (TAILLIGHTS)
Result:
NG
GO TO PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [08/2020 - 12/2021]
Result:
OK
See step 2
- PERFORM ACTIVE TEST USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Main Body / Active Test.
- Perform the Active Test according to the display on the Techstream.
Body Electrical > Main Body > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Front Fog Light Relay Front fog lights ON/OFF Light control switch in tail position Body Electrical > Main Body > Active Test
Tester Display Front Fog Light Relay OK
Front fog lights come on.
Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [08/2020 - 12/2021]
Result:
NG
See step 3
- CHECK HARNESS AND CONNECTOR (FR FOG RELAY - BATTERY)
- Remove the FR FOG relay from the No. 4 relay block assembly.
- Measure the voltage according to the value(s) in the chart below.
Standard Voltage
Tester Connection Condition Specified Condition Relay terminal 5 -Body ground Always 11 to 14 V *1 No. 4 Relay Block Assembly *a FR FOG relay terminal Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- CHECK HARNESS AND CONNECTOR (FR FOG RELAY INPUT VOLTAGE)
- Measure the voltage according to the value(s) in the chart below.
Standard Voltage
Tester Connection Condition Specified Condition Relay terminal 2 - Body ground Light control switch TAIL or HEAD 11 to 14 V *1 No. 4 Relay Block Assembly *a FR FOG relay terminal Result
Proceed to OK NG
Result:
NG
See step 10
Result:
OK
See step 5
- Measure the voltage according to the value(s) in the chart below.
- INSPECT FR FOG RELAY
- Inspect the FR FOG relay.
Refer to ON-VEHICLE INSPECTION [02/2017 - ]
Result
Result Proceed to OK (for TMMT Made) A OK (for TMC Made) B NG C
Result:
B
See step 7
Result:
C
REPLACE FR FOG RELAY
Result:
A
See step 6
- Inspect the FR FOG relay.
- CHECK HARNESS AND CONNECTOR (FR FOG RELAY - FOG LIGHT ASSEMBLY RH AND FOG LIGHT ASSEMBLY LH)
- Disconnect the B15*1 or B13*2 fog light assembly LH connector.
- *1: for LED Fog Light
- *1: for Halogen Fog Light
- Disconnect the B16*1 or B14*2 fog light assembly RH connector.
- *1: for LED Fog Light
- *1: for Halogen Fog Light
- Measure the voltage according to the value(s) in the chart below.
Standard Resistance
Tester Connection Condition Specified Condition Relay terminal 3 - B15-2 (B)*1 Always Below 1 Ω Relay terminal 3 - B13-1 (B)*2 Always Below 1 Ω Relay terminal 3 - B16-2 (B)*1 Always Below 1 Ω Relay terminal 3 - B14-1 (B)*2 Always Below 1 Ω Relay terminal 3 or B15-2 (B) - Body ground*1 Always 10 kΩ or higher Relay terminal 3 or B13-1 (B) - Body ground*2 Always 10 kΩ or higher Relay terminal 3 or B16-2 (B) - Body ground*1 Always 10 kΩ or higher Relay terminal 3 or B14-1 (B) - Body ground*2 Always 10 kΩ or higher - *1: for LED Fog Light
- *1: for Halogen Fog Light
Result
Proceed to OK NG
Result:
OK
See step 8
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- Disconnect the B15*1 or B13*2 fog light assembly LH connector.
- CHECK HARNESS AND CONNECTOR (FR FOG RELAY - FOG LIGHT ASSEMBLY RH AND FOG LIGHT ASSEMBLY LH)
- Disconnect the B16 fog light assembly LH connector.
- Disconnect the B15 fog light assembly RH connector.
- Measure the voltage according to the value(s) in the chart below.
Standard Resistance
Tester Connection Condition Specified Condition Relay terminal 3 - B16-2 (B) Always Below 1 Ω Relay terminal 3 - B15-2 (B) Always Below 1 Ω Relay terminal 3 or B16-2 (B) - Body ground Always 10 kΩ or higher Relay terminal 3 or B15-2 (B) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 8
- CHECK HARNESS AND CONNECTOR (FR FOG RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Disconnect the 3A instrument panel junction block assembly connector.
- Measure the voltage according to the value(s) in the chart below.
Standard Resistance
Tester Connection Condition Specified Condition Relay terminal 1 - 3A-52 Always Below 1 Ω Relay terminal 1 or 3A-52 - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 9
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
- Remove the instrument panel junction block assembly.
Refer to REMOVAL [08/2020 - 12/2021]
- Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
- Measure the resistance according to the value(s) in the chart below.
*a Component without harness connected
(Instrument Panel Junction Block Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition 3A-52 - MB-7 (FFGO) Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [08/2020 - 12/2021]
Result:
NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [08/2020 - 12/2021]
- Remove the instrument panel junction block assembly.
- CHECK HARNESS AND CONNECTOR (FR FOG RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Disconnect the 3D instrument panel junction block assembly connector.
- Measure the voltage according to the value(s) in the chart below.
Standard Resistance
Tester Connection Condition Specified Condition Relay terminal 2 - 3D-11 Always Below 1 Ω Relay terminal 2 or 3D-11 - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [08/2020 - 12/2021]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR