Inspection [02/2017 - ]: Procedure
- INSPECT FUEL LID OPENER SWITCH
- Check the resistance.
*a Component without harness connected
(Fuel Lid Opener Switch)- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 4 (IG) - 1 (E) Pressed (ON) Below 1 Ω 4 (IG) - 1 (E) Not pressed (OFF) 10 kΩ or higher If the result is not as specified, replace the fuel lid opener switch.
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Fuel Lid Opener Switch)Check that the LED illuminates.
- Apply battery voltage to the fuel lid opener switch and check that the fuel lid opener switch illuminates.
OK
Measurement Condition Specified Condition Battery positive (+) → 3 (ILL+) LED illuminates Battery negative (-) → 2 (ILL-) If the result is not as specified, replace the fuel lid opener switch.
- Apply battery voltage to the fuel lid opener switch and check that the fuel lid opener switch illuminates.
- Check the resistance.