Inspection [02/2017 - ]: Procedure
- INSPECT LIGHT CONTROL RHEOSTAT
*a Component without harness connected
(Light Control Rheostat)*b Knob Inspect the light control rheostat.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 7 (T) - 1 (E) Always 8 to 12 kΩ 3 (RV) - 1 (E) Knob turned fully upward 8 to 12 kΩ 3 (RV) - 1 (E) Knob turned fully downward Below 50 Ω 3 (RV) - 1 (E) Knob turned from fully upward to fully downward 8 to 12 kΩ → Below 50 Ω If the result is not as specified, replace the light control rheostat.
- Measure the resistance according to the value(s) in the table below.
*a (Light Control Rheostat)
Component without harness connected*b Knob Inspect the TAIL cancel switch.
HINT:
The TAIL cancel switch is built into the light control rheostat.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 7 (T) - 5 (TC) Knob turned fully upward
(TAIL cancel condition)10 kΩ or higher 7 (T) - 5 (TC) Knob not turned fully upward Below 1 Ω If the result is not as specified, replace the light control rheostat.
- Measure the resistance according to the value(s) in the table below.