LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2021 >> C-HR LE >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Meter / Gauge / Display - Diagnostic Codes & Symptom Tests >> Meter / Gauge System >> Operating Light Control Rheostat does not Change Light Brightness [02/2017 - ] >> Procedure

Operating Light Control Rheostat does not Change Light Brightness [02/2017 - ]: Procedure

  1. PERFORM ACTIVE TEST USING TECHSTREAM (LIGHT CONTROL RHEOSTAT) 
    1. Connect the Techstream to the DLC3.
    2. Turn the ignition switch to ON.
    3. Turn the Techstream on.
    4. Enter the following menus: Body Electrical / Combination Meter / Data List.
    5. Read the Data List according to the display on the Techstream.
      1. Combination Meter.

        Body Electrical > Combination Meter > Data List 

        Tester Display Measurement Item Normal Condition Diagnostic Note
        Tail Cancel SW Tail cancel switch/
        OFF or ON
        OFF: Tail cancel switch off
        ON: Tail cancel switch on
        -
        Rheostat value Rheostat value/
        Min.: 0
        Max.: 100
        Light control rheostat switch is Dark (0) → Bright (100) Unit: %

        Body Electrical > Combination Meter > Data List 

        Tester Display
        Tail Cancel SW
        Rheostat value

      Result

      Result Proceed to
      The Data List values of ECUs match. A
      The Data List values of ECUs do not match. B

    Result: 

    A 

    REPLACE COMBINATION METER ASSEMBLY. Refer to  REMOVAL [02/2017 - 08/2020]  , or refer to  REMOVAL [08/2020 - ] 

    Result: 

    B 

    See step  2

  2. INSPECT LIGHT CONTROL RHEOSTAT 
    1. Remove the light control rheostat

      Refer to REMOVAL [02/2017 - ]

    2. Inspect the light control rheostat

      Refer to INSPECTION [02/2017 - ]

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPLACE LIGHT CONTROL RHEOSTAT. Refer to  REMOVAL [02/2017 - ] 

    Result: 

    OK 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (LIGHT CONTROL RHEOSTAT - COMBINATION METER ASSEMBLY) 
    1. Disconnect the F4 combination meter assembly connector.
    2. Disconnect the F128 light control rheostat connector.
    3. Measure the resistance according to the value(s) in the chart below.

      Standard Resistance (Check for Open)

      Tester Connection Condition Specified Condition
      F4-25 (SW1) - F128-7 (T) Always Below 1 Ω
      F4-26 (SW2) - F128-3 (RV) Always Below 1 Ω
      F4-20 (SW3) - F128-1 (E) Always Below 1 Ω
      F4-24 (TC) - F128-5 (TC) Always Below 1 Ω

      Standard Resistance (Check for Short)

      Tester Connection Condition Specified Condition
      F4-24 (TC) - Body ground Always 10 kΩ or higher
      F4-25 (SW1) - Body ground Always 10 kΩ or higher
      F4-26 (SW2) - Body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE COMBINATION METER ASSEMBLY. Refer to  REMOVAL [02/2017 - 08/2020]  , or refer to  REMOVAL [08/2020 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR