Entire Combination Meter does not Operate [02/2017 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)
- Disconnect the F4 combination meter assembly connector.
- Measure the resistance according to the value(s) in the chart below.
Standard Resistance
Tester Connection Condition Specified Condition F4-21 (ET) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the chart below.
Standard Voltage
Tester Connection Switch Condition Specified Condition F4-39 (IG+) - Body ground Ignition switch off Below 1 V Ignition switch ON 11 to 14 V F4-40 (B) - Body ground Always 11 to 14 V Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [02/2017 - 08/2020] , or refer to REMOVAL [08/2020 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR