DTC C1254: Pressure Sensor or Switch [08/2015 - ]: Procedure
- READ VALUE USING TECHSTREAM (ACCUMULATOR SENSOR)
- Turn the ignition switch off.
- Connect the Techstream to the DLC3.
- Depress the brake pedal more than 40 times.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Chassis / ABS/VSC/TRAC / Data List.ABS/VSC/TRAC
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Accumulator Sensor Accumulator pressure sensor reading/ Min.: 0.00 V, Max.: 5.00 V 3.58 to 5 V If the value is constant regardless of the pump operation, an accumulator pressure sensor malfunction is suspected. - Check the accumulator output value.RESULT
Result Proceed to Output value is within "Normal Condition" range A Output value is out of "Normal Condition" range B Output value is constant regardless of pump operation
Result:
B
REPLACE MASTER CYLINDER SOLENOID
(Refer to DISASSEMBLY [08/2015 - ] )
Result:
A
See step 2
- RECONFIRM DTC
- Clear the DTCs (Refer to DTC CHECK / CLEAR [08/2015 - 08/2019] , or refer to DTC CHECK / CLEAR [08/2019 - ] ).
- Turn the ignition switch off.
- Depress the brake pedal more than 40 times.
- Turn the ignition switch to ON.
- Wait until the pump motor stops.
- Wait for 15 minutes.
- Depress the brake pedal and release it.
- Check if the same DTC is output (Refer to DTC CHECK / CLEAR [08/2015 - 08/2019]
, or refer to DTC CHECK / CLEAR [08/2019 - ]
).RESULT
Result Proceed to DTC is output A DTC is not output B
Result:
A
REPLACE MASTER CYLINDER SOLENOID
(Refer to DISASSEMBLY [08/2015 - ] )
Result:
B
USE SIMULATION METHOD TO CHECK
(Refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2015 - 08/2019] , or refer to HOW TO PROCEED WITH TROUBLESHOOTING [08/2019 - ] )