DTC P17AC: Transfer Shift Motor Limit Switch Circuit [08/2019 - ]: Description
WARNING: This page is about a different variant/trim than selected.
When the transfer switches modes, the TL1, TL2, TL3, B and L4 terminals of the limit switch are in one of the ON/OFF combinations listed in the table below.
| Terminal | When H2 | Switching between H2 and H4 | Switching between H4 and H2 | When H4 | Switching between H4 and L4 | Switching between L4 and H4 | When L4 |
|---|---|---|---|---|---|---|---|
| TL1 | ON (GND) | ON (GND) | ON (GND) | OFF (OPEN) | OFF (OPEN) | OFF (OPEN) | OFF (OPEN) |
| TL2 | OFF (OPEN) | OFF (OPEN) | OFF (OPEN) | OFF (OPEN) | ON (GND) | ON (GND) | ON (GND) |
| TL3 | OFF (OPEN) | ON (GND) | ON (GND) | ON (GND) | ON (GND) | ON (GND) | OFF (OPEN) |
| B | OFF (OPEN) | OFF (OPEN) | ON (GND) | ON (GND) | ON (GND) | ON (GND) | ON (GND) |
| L4 | OFF (OPEN) | OFF (OPEN) | OFF (OPEN) | OFF (OPEN) | OFF (OPEN) | ON (GND) | ON (GND) |
A malfunction is detected depending on the combination of the 3 circuits that make up the limit switch of the transfer shift actuator assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P17AC | Transfer Shift Motor Limit Switch Circuit |
|
|