Recirculated/Fresh Air Modes Switch without User Input [02/2019 - 08/2020]: Procedure
- CHECK CUSTOMIZE SETTING
- Use the following customize setting methods to check if the automatically fresh/recirculation mode is "ON". If the setting is on, select the setting to "OFF".
Refer to CUSTOMIZE PARAMETERS [02/2019 - 10/2022]
- Check setting using Techstream
- Check setting by multi-display
OK
Customize setting is "OFF".
Result
Proceed to OK NG
Result:
NG
CHANGE CUSTOMIZE SETTING IS ON
Result:
OK
See step 2
- Use the following customize setting methods to check if the automatically fresh/recirculation mode is "ON". If the setting is on, select the setting to "OFF".
- READ VALUE USING TECHSTREAM (AMBIENT TEMP SENSOR)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Ambient Temp Sensor Thermistor assembly Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)Actual ambient temperature displayed Thermistor assembly system malfunction - When open circuit: -23.30°C (-9.94°F)
- When short circuit: 65.95°C (150.71°F)
Body Electrical > Air Conditioner > Data List
Tester Display Ambient Temp Sensor OK
The value of the display does not change frequently.
Result
Proceed to OK NG
Result:
NG
GO TO AMBIENT TEMPERATURE DISPLAY SYSTEM. Refer to Ambient Temperature Display System [02/2019 - 06/2020] , or refer to Ambient Temperature Display System [06/2020 - 08/2020]
Result:
OK
See step 3
- READ VALUE USING TECHSTREAM (COOLANT TEMPERATURE)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Powertrain / Engine / Data List.
- Read the Data List according to the display on the Techstream.
Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Coolant Temperature Engine coolant temperature Min.: -40°C (-40°F), Max.: 140°C (284°F) 75 to 100°C (167 to 212°F): After warming up This is the engine coolant temperature.
HINT:- After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).
- After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.
- If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.
- Check if the engine overheats if the value indicated is higher than 135°C (275°F).
Powertrain > Engine > Data List
Tester Display Coolant Temperature OK
The value of the display does not change frequently.
Result
Proceed to OK NG
Result:
NG
GO TO COOLING SYSTEM. Refer to ON-VEHICLE INSPECTION [02/2019 - ]
Result:
OK
See step 4
- CHECK REFRIGERANT PRESSURE
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Regulator Pressure Sensor Air conditioner pressure sensor Min.: -456.6 kPaG (gauge)
Max.: 3294.3 kPaG (gauge)Actual refrigerant pressure displayed - Refrigerant line (gas leak etc.)
- Air conditioner pressure sensor system malfunction
Body Electrical > Air Conditioner > Data List
Tester Display Regulator Pressure Sensor - Install a manifold gauge set.
- for HFC-134a (R134a): Refer to ON-VEHICLE INSPECTION [11/2018 - 08/2020]
- for HFO-1234yf (R1234yf): Refer to ON-VEHICLE INSPECTION [02/2019 - ]
- Read the manifold gauge pressure when the following conditions are met.
- Prepare the vehicle according to the table below.MEASUREMENT CONDITION:
Item Condition Vehicle Condition Ignition switch ON (READY) Doors Fully closed (windows also fully closed) A/C Switch On Recirculation/fresh Control Switch Recirculation Set Temperature MAX COLD Blower Speed HI Air Conditioning Air Inlet Temperature 25 to 35°C (77 to 95°F) Standard Pressure
Low pressure side
150 to 250 kPa (1.5 to 2.5 kgf/cm2 , 22 to 36 psi)
High pressure side
1370 to 1570 kPa (14 to 16 kgf/cm2 , 199 to 228 psi)
- Prepare the vehicle according to the table below.
- Compare the values displayed in the Data List and on the manifold gauge.
OK
The values displayed in the Data List and on the manifold gauge match.
Result
Proceed to OK NG
Result:
OK
GO TO ON-VEHICLE INSPECTION (CHECK REFRIGERANT PRESSURE USING GAUGE). Refer to PROCEDURE - Step 2
Result:
NG
REPLACE AIR CONDITIONER PRESSURE SENSOR. Refer to REMOVAL [11/2018 - 08/2020]