No Heating at All [02/2019 - ]: Procedure
- READ VALUE USING TECHSTREAM (COOLANT TEMPERATURE)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Powertrain / Engine / Data List.
- Read the Data List according to the display on the Techstream.
Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Coolant Temperature Engine coolant temperature Min.: -40°C (-40°F), Max.: 140°C (284°F) 75 to 100°C (167 to 212°F): After warming up This is the engine coolant temperature.
HINT:- After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).
- After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.
- If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.
- Check if the engine overheats if the value indicated is higher than 135°C (275°F).
Powertrain > Engine > Data List
Tester Display Coolant Temperature OK
The value of the display does not change frequently.
Result
Proceed to OK NG
Result:
NG
GO TO COOLING SYSTEM. Refer to ON-VEHICLE INSPECTION [02/2019 - ]
Result:
OK
See step 2
- PERFORM ACTIVE TEST USING TECHSTREAM (SERVO PULSE)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Active Test.
- Check the operation by referring to the table below.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383Operates between 165 to 257 pulses Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
Max.: 383Operates between 255 to 347 pulses Body Electrical > Air Conditioner > Active Test
Tester Display Air Mix Servo Targ Pulse(D) Body Electrical > Air Conditioner > Active Test
Tester Display Air Mix Servo Targ Pulse(P) OK
Damper servo motor is operated.
Result
Proceed to OK NG
Result:
OK
REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY. Refer to DISASSEMBLY [02/2019 - 08/2020] , or refer to DISASSEMBLY [08/2020 - ]
Result:
NG
GO TO DIAGNOSTIC TROUBLE CODE CHART (FOR SERVO MOTOR OF APPLICABLE ABNORMAL OPERATION). Refer to DIAGNOSTIC TROUBLE CODE CHART [02/2019 - 06/2020] , or refer to DIAGNOSTIC TROUBLE CODE CHART [06/2020 - 08/2020] , or refer to DIAGNOSTIC TROUBLE CODE CHART [08/2020 - ]