Air Vent cannot be Switched [11/2018 - ]: Procedure
- CHECK NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY
- Check that the No. 1 air conditioning radiator damper servo sub-assembly is installed correctly.
OK
No. 1 air conditioning radiator damper servo sub-assembly is installed correctly.
Result
Proceed to OK NG
Result:
NG
REINSTALL NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY
Refer to REASSEMBLY [11/2018 - 02/2019] , or refer to REASSEMBLY [02/2019 - 08/2020] , or refer to REASSEMBLY [08/2020 - ]
Result:
OK
See step 2
- Check that the No. 1 air conditioning radiator damper servo sub-assembly is installed correctly.
- CHECK FOR DTC
- Check for DTCs.
Refer to DTC CHECK / CLEAR [11/2018 - 02/2019] , or refer to DTC CHECK / CLEAR [02/2019 - ]
OK
DTC B1443 is not output.
Result
Proceed to OK NG
Result:
OK
REPAIR OR REPLACE AIR CONDITIONING RADIATOR ASSEMBLY
Result:
NG
GO TO DTC B1443
Refer to DTC B1443: Air Outlet Damper Control Servo Motor Circuit [11/2018 - 02/2019] , or refer to DTC B1443: Air Outlet Damper Control Servo Motor Circuit [02/2019 - 08/2020] , or refer to DTC B1443: Air Outlet Damper Control Servo Motor Circuit [08/2020 - ]
- Check for DTCs.