Air Vent Temperature does not Change and Right Vent is Different from Left and Vice Versa (Same Left/Right Temperature Setting) [11/2018 - 02/2019]: Procedure
- CHECK MALFUNCTION STATUS
Result
Result Proceed to While cooling A While heater B Result:
B
See step 6
Result:
A
See step 2
- CHECK REFRIGERANT SHORTAGE
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
Body Electrical > Air Conditioner > Utility
Tester Display Refrigerant Gas Volume Check - Check that the following conditions are met and perform the refrigerant shortage check according to the display on the Techstream.MEASUREMENT CONDITION:
Item Condition Vehicle Condition Power switch on (READY) A/C Switch On Ambient Temperature*1 0 to 49°C (32 to 120°F) Air Conditioning Air Inlet Temperature*2 25 to 35°C (77 to 95°F) Set Temperature MAX COLD Recirculation/fresh Control Switch Recirculation Air Vent Damper Position FACE Blower Speed HI HINT:
- Refer to the Techstream operator's manual for further details.
- A message indicating a refrigerant shortage is displayed on the Techstream and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.
- DTCs are not stored when performing the refrigerant shortage check using the Techstream.
- *1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.
- *2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.
Result
Result Amount of Refrigerant Refrigerant shortage Insufficient or leakage Refrigerant correct Correct OK
"Refrigerant correct" is displayed on Techstream.
Result
Proceed to OK NG
Result:
NG
CHARGE SYSTEM WITH REFRIGERANT
- for HFC-134a (R134a): Refer to REPLACEMENT [11/2018 - 08/2020]
- for HFO-1234yf (R1234yf): Refer to REPLACEMENT [11/2018 - 02/2019]
Result:
OK
See step 3
- PERFORM ACTIVE TEST USING TECHSTREAM (SERVO PULSE)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Active Test.
- Check the operation by referring to the table below.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383Operates between 165 to 257 pulses Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
Max.: 383Operates between 255 to 347 pulses Body Electrical > Air Conditioner > Active Test
Tester Display Air Mix Servo Targ Pulse(D) Body Electrical > Air Conditioner > Active Test
Tester Display Air Mix Servo Targ Pulse(P) OK
Damper servo motor is operated.
Result
Proceed to OK NG
Result:
NG
GO TO DTC OF APPLICABLE SERVO MOTOR OPERATING ABNORMALLY
Refer to DIAGNOSTIC TROUBLE CODE CHART [11/2018 - 02/2019]
Result:
OK
See step 4
- CHECK HARNESS AND CONNECTOR (AUTOMATIC LIGHT CONTROL SENSOR - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))
- Disconnect the H1 automatic light control sensor connector.
- Disconnect the G44 main body ECU (multiplex network body ECU) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition H1-1 (CLTB) - G44-23 (CLTB) Always Below 1 Ω H1-2 (CLTE) - G44-25 (CLTE) Always Below 1 Ω H1-4 (CLTS) - G44-24 (CLTS) Always Below 1 Ω H1-1 (CLTB) or G44-23 (CLTB) - Other terminals and body ground Always 10 kΩ or higher H1-2 (CLTE) or G44-25 (CLTE) - Other terminals and body ground Always 10 kΩ or higher H1-4 (CLTS) or G44-24 (CLTS) - Other terminals and body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 5
- INSPECT AUTOMATIC LIGHT CONTROL SENSOR
- Remove the automatic light control sensor.
Refer to REMOVAL [11/2018 - 02/2019]
- Inspect the automatic light control sensor.
Refer to ON-VEHICLE INSPECTION [11/2018 - ]
Result
Proceed to OK NG
Result:
OK
GO TO ON-VEHICLE INSPECTION
Refer to PROCEDURE - Step 2
Result:
NG
REPLACE AUTOMATIC LIGHT CONTROL SENSOR
Refer to REMOVAL [11/2018 - 02/2019]
- Remove the automatic light control sensor.
- BLEED AIR FROM COOLANT
Refer to REPLACEMENT [11/2018 - ]
Result
Proceed to NEXT Result:
NEXT
See step 7
- CHECK OPERATION (AIR CONDITIONING SYSTEM)
- Check that there is not a difference in temperature between the left and right air outlets.
OK
There is not a difference in temperature between the left and right air outlets.
Result
Proceed to OK NG
Result:
OK
END (FAILURE DUE TO AIR ENTERING COOLANT)
Result:
NG
See step 8
- Check that there is not a difference in temperature between the left and right air outlets.
- PERFORM ACTIVE TEST USING TECHSTREAM (SERVO PULSE)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Air Conditioner / Active Test.
- Check the operation by referring to the table below.
Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) operation Min.: 128
Max.: 383Operates between 165 to 257 pulses Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) operation Min.: 128
Max.: 383Operates between 255 to 347 pulses Body Electrical > Air Conditioner > Active Test
Tester Display Air Mix Servo Targ Pulse(D) Body Electrical > Air Conditioner > Active Test
Tester Display Air Mix Servo Targ Pulse(P) OK
Damper servo motor is operated.
Result
Proceed to OK NG
Result:
OK
REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY
Refer to DISASSEMBLY [11/2018 - 02/2019]
Result:
NG
GO TO DIAGNOSTIC TROUBLE CODE CHART (FOR SERVO MOTOR OF APPLICABLE ABNORMAL OPERATION)