DTC B1423: Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure [08/2020 - ]: Description
WARNING: This page is about a different variant/trim than selected.
This DTC is stored if refrigerant pressure on the high pressure side is extremely low (196 kPa (2.0 kgf/cm2 , 28 psi)) or less) or extremely high (2812 kPa (28.7 kgf/cm2 , 408 psi)) or more). The air conditioner pressure sensor, which is installed to the high pressure side pipe to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1423 | Pressure Sensor Circuit |
|
|
- |