On-Vehicle Inspection [10/2019 - 08/2020]: Procedure
- CHECK AUXILIARY BATTERY
- Check that the auxiliary battery cables are connected to the correct terminals.
If they are not, connect them properly.
- Check the auxiliary battery for damage and deformation. If severe damage, deformation or leakage is found, replace the auxiliary battery.
- Check that the auxiliary battery cables are connected to the correct terminals.
- CHECK AUXILIARY BATTERY VOLTAGE
- Turn the ignition switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.
- Measure the auxiliary battery voltage according to the value(s) in the table below.
Result
Tester Connection Condition Specified Condition Result Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 20°C (68°F), Ignition switch off 12.0 V or higher Auxiliary battery is OK 12.0 V or less Recharge auxiliary battery
- RECHARGE AUXILIARY BATTERY
- Recharge the auxiliary battery.
HINT:
- Recharge the auxiliary battery according to the charger's instructions.
- Apply the appropriate charging current according to the type of auxiliary battery shown in the table below.
Charge Method Charging Current Normal Below 5 A Quick Below 15 A - Turn the ignition switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.
- Measure the auxiliary battery voltage according to the value(s) in the table below.
Result
Tester Connection Condition Specified Condition Result Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 20°C (68°F), Ignition switch off 12.0 V or higher Auxiliary battery is OK 12.0 V or less Recharge auxiliary battery
- Recharge the auxiliary battery.
- CHECK AUXILIARY BATTERY TERMINAL, FUSIBLE LINK AND FUSE
- Check that the auxiliary battery terminals are not loose or corroded.
Positive (+) Auxiliary Battery Terminal
Torque: 5.4 N*m (55 kgf*cm, 48 in.*lbf)
Negative (-) Auxiliary Battery Terminal
Torque: 5.4 N*m (55 kgf*cm, 48 in.*lbf)
If a terminal is loose or corroded, tighten or clean the terminal.
- Measure the resistance of each fusible link and fuse for the auxiliary battery charging system.
Standard resistance
Below 1 Ω
If the result is not as specified, replace the fusible link or fuse as necessary.
- Check that the auxiliary battery terminals are not loose or corroded.
- CHECK AMD TERMINAL WARNING:
- Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the service information.
Refer to PRECAUTION [11/2018 - ]
- To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.
- Remove the service plug grip.
Refer to REMOVAL [10/2019 - 06/2020] , or refer to REMOVAL [06/2020 - 08/2020]
- Check that the AMD terminal is connected securely, and there is no contact problem.
If there are any arc marks, replace the affected parts.
- Check that the nut for the AMD terminal is tightened to the specified torque.
*a Inverter with Converter Assembly Side *b No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly Side Inverter with Converter Assembly Side
Torque: 10 N*m (102 kgf*cm, 7 ft.*lbf)
No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly Side
Torque: 8.0 N*m (82 kgf*cm, 71 in.*lbf)
If there are no arc marks and the AMD terminal connection is faulty, connect the AMD terminal securely.
- Install the service plug grip.
Refer to INSTALLATION [11/2018 - ]
- Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the service information.
- CHECK DC/DC CONVERTER FUNCTION
- Connect the AC/DC 400 A probe to the positive (+) auxiliary battery cable.
*a Probe Direction *b Current Flowing into Auxiliary Battery - Turn the ignition switch to on (READY) and leave the vehicle as is until the electric current flowing to the auxiliary battery becomes 10 A or less.
- Turn on the high beam headlights, and turn the blower motor switch to the HI position and the rear window defogger on.
- Measure the current and voltage according to the value(s) in the table below.
*a Probe Direction *b Current Flowing from Auxiliary Battery Result
Item Tester Connection Condition Specified Condition Current flowing from auxiliary battery Positive (+) auxiliary battery cable Ignition switch ON
(The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on.)0 A or less
(No current from auxiliary battery)Auxiliary battery voltage Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 12.5 to 15 V If the result is not as specified, replace the inverter with converter assembly.
- Connect the AC/DC 400 A probe to the positive (+) auxiliary battery cable.