LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2020 >> RAV4 XLE, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 50 (Power Back Door System (HV) - Diagnostic Codes & Symptom Tests) >> POWER BACK DOOR SYSTEM (for HV Model) >> Power Back Door Warning System does not Operate [11/2018 - 10/2023] >> Procedure

Power Back Door Warning System does not Operate [11/2018 - 10/2023]: Procedure

WARNING: This page is about a different variant/trim than selected.
  1. CHECK OPERATION 
    1. Check power back door system operation.

      Refer to OPERATION CHECK [11/2018 - 10/2023]

      Result

      Result Proceed to
      Hazard warning light does not come on A
      Power back door warning buzzer does not operate B

    Result: 

    See step  6

    Result: 

    See step  2

  2. CHECK WIRELESS DOOR LOCK CONTROL SYSTEM (HAZARD ANSWER-BACK FUNCTION) 
    1. Check wireless door lock operation.

      Refer to OPERATION CHECK [11/2018 - 02/2019] , or refer to OPERATION CHECK [02/2019 - 08/2020] , or refer to OPERATION CHECK [08/2020 - 10/2023]

      OK

      Hazard answer-back function operates normally.

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    GO TO WIRELESS DOOR LOCK CONTROL SYSTEM. Refer to  HOW TO PROCEED WITH TROUBLESHOOTING [11/2018 - ] 

    Result: 

    OK 

    See step  3

  3. REPLACE MULTIPLEX NETWORK DOOR ECU 
    1. Temporarily replace the multiplex network door ECU with a new or normally functioning one.

      Refer to REMOVAL [11/2018 - 10/2023]

      Result

      Proceed to
      NEXT

    Result: 

    NEXT 

    See step  4

  4. INITIALIZE MULTIPLEX NETWORK DOOR ECU 
    1. Perform the initialization for the multiplex network door ECU.

      Refer to INITIALIZATION [11/2018 - 10/2023]

      Result

      Proceed to
      NEXT

    Result: 

    NEXT 

    See step  5

  5. CHECK POWER BACK DOOR SYSTEM 
    1. Check that the power back door hazard warning lights operate normally.

      Refer to OPERATION CHECK [11/2018 - 10/2023]

      OK

      The power back door hazard warning lights operate normally.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    END (MULTIPLEX NETWORK DOOR ECU WAS DEFECTIVE) 

    Result: 

    NG 

    REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to  REMOVAL [11/2018 - 02/2019]  , or refer to  REMOVAL [02/2019 - 10/2019]  , or refer to  REMOVAL [10/2019 - 08/2020]  , or refer to  REMOVAL [08/2020 - 12/2021]  , or refer to  REMOVAL [12/2021 - 10/2022]  , or refer to  REMOVAL [10/2022 - 10/2023] 

  6. PERFORM ACTIVE TEST USING TECHSTREAM 
    1. Perform the Active Test according to the display on the Techstream.

      Refer to DATA LIST / ACTIVE TEST [11/2018 - 10/2023]

      Body Electrical > Back Door > Active Test 

      Tester Display Measurement Item Control Range Diagnostic Note
      PBD Buzzer Power back door warning buzzer sound ON or OFF -

      Body Electrical > Back Door > Active Test 

      Tester Display
      PBD Buzzer

      OK

      Power back door warning buzzer sounds.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE MULTIPLEX NETWORK DOOR ECU. Refer to  REMOVAL [11/2018 - 10/2023] 

    Result: 

    NG 

    See step  7

  7. CHECK HARNESS AND CONNECTOR (POWER BACK DOOR WARNING BUZZER - MULTIPLEX NETWORK DOOR ECU AND BODY GROUND) 
    1. Disconnect the Q2 power back door warning buzzer connector.
    2. Disconnect the R18 multiplex network door ECU connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      Q2-1 (BZR+) - R18-16 (BZR+) Always Below 1 Ω
      Q2-2 (BZR-) - Body ground Always Below 1 Ω
      Q2-1 (BZR+) or R18-16 (BZR+) - Body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR 

    Result: 

    OK 

    See step  8

  8. REPLACE POWER BACK DOOR WARNING BUZZER 
    1. Temporarily replace the power back door warning buzzer with a new or normally functioning one.

      Refer to REMOVAL [11/2018 - 02/2019] , or refer to REMOVAL [02/2019 - 10/2019] , or refer to REMOVAL [10/2019 - 08/2020] , or refer to REMOVAL [08/2020 - 12/2021] , or refer to REMOVAL [12/2021 - 10/2022] , or refer to REMOVAL [10/2022 - 10/2023]

      Result

      Proceed to
      NEXT

    Result: 

    NEXT 

    See step  9

  9. CHECK POWER BACK DOOR SYSTEM 
    1. Check that the power back door warning buzzer operates normally.

      Refer to OPERATION CHECK [11/2018 - 10/2023]

      OK

      Power back door warning buzzer sounds.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    END (POWER BACK DOOR WARNING BUZZER WAS DEFECTIVE) 

    Result: 

    NG 

    REPLACE MULTIPLEX NETWORK DOOR ECU. Refer to  REMOVAL [11/2018 - 10/2023]