ECM Communication Stop Mode [11/2018 - 02/2019]: Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK FOR OPEN IN CAN BUS WIRE (ECM MAIN WIRE AND BRANCH WIRE)
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Disconnect the ECM connector.
*a Front view of wire harness connector
(to ECM) - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A24-8 (CANH) - A24-18 (CANL) Cable disconnected from negative (-) auxiliary battery terminal 108 to 132 Ω A24-7 (CAN+) - A24-17 (CAN-) Cable disconnected from negative (-) auxiliary battery terminal 54 to 69 Ω Result
Result Proceed to OK A NG (No. 3 CAN junction connector main wire) B NG (No. 4 CAN junction connector branch wire) C
Result:
B
REPAIR OR REPLACE CAN MAIN WIRE OR CONNECTOR
Result:
C
REPAIR OR REPLACE CAN BRANCH WIRE OR CONNECTOR
Result:
A
See step 2
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Measure the resistance according to the value(s) in the table below.
*a Front view of wire harness connector
(to ECM)Standard Resistance
Tester Connection Condition Specified Condition A24-45 (EC) - Body ground Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω A24-10 (E1) - Body ground Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω A24-36 (E2) - Body ground Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω A24-54 (E1D1) - Body ground Cable disconnected from negative (-) auxiliary battery terminal Below 1 Ω - Reconnect the cable to the negative (-) auxiliary battery terminal.NOTE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Refer to INITIALIZATION [11/2018 - 02/2019]
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition A24-1 (BATT) - Body ground Power switch off 11 to 14 V A24-9 (+B) - Body ground Terminal A24-15 (MREL) connected to body ground 11 to 14 V A24-35 (+B2) - Body ground Terminal A24-15 (MREL) connected to body ground 11 to 14 V A24-2 (IGSW) - Body ground Power switch on (IG) 11 to 14 V Power switch off Below 1 V Result
Proceed to OK NG
Result:
OK
REPLACE ECM
Refer to REMOVAL [11/2018 - 02/2019]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- Measure the resistance according to the value(s) in the table below.