Installation [08/2020 - ]: Procedure
WARNING: This page is about a different variant/trim than selected.
- INSTALL FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY)
- Connect the flow shutting valve (water by-pass hose assembly) to the water by-pass outlet sub-assembly and slide the clip to secure it.
*a View A *b 90° *c Upper Side *d RH Side *e 2 to 7 mm (0.0787 to 0.276 in.) NOTE:- Make sure to slide the flow shutting valve (water by-pass hose assembly) until it contacts the hose stopper of the water by-pass outlet sub-assembly.
- Make sure that the tabs of the clip are within the area shown in the illustration.
- Connect the flow shutting valve (water by-pass hose assembly) with the bolt.
Torque: 19 N.m (194 kgf/cm, 14 ft.lbf)
- Connect the No. 2 water by-pass pipe sub-assembly with the bolt.
Torque: 19 N.m (194 kgf/cm, 14 ft.lbf)
- Connect the inlet heater water hose connector to the flow shutting valve (water by-pass hose assembly).NOTE:
Check that there is no damage or foreign matter on the connecting parts of the water lines.
*a Protrusion *b Cutout Align the protrusions of the inlet heater water hose connector with the cutouts in the flow shutting valve (water by-pass hose assembly) and securely insert the inlet heater water hose connector to the stopper of the pipe.
- Push in the retainer.
*a Retainer Push Push in - Check that the flow shutting valve (water by-pass hose assembly) and inlet heater water hose connector are securely connected by pulling on them.
- Connect the outlet heater water hose connector to the No. 2 water by-pass pipe sub-assembly.NOTE:
Check that there is no damage or foreign matter on the connecting parts of the water lines.
- Align the protrusion of the No. 2 water by-pass pipe sub-assembly with the cutout in the outlet heater water hose connector and securely insert the outlet heater water hose connector to the stopper of the pipe.
*a Protrusion *b Cutout - Push in the retainer.
*a Retainer Push Push in - Check that the No. 2 water by-pass pipe sub-assembly and outlet heater water hose connector are securely connected by pulling on them.
- Align the protrusion of the No. 2 water by-pass pipe sub-assembly with the cutout in the outlet heater water hose connector and securely insert the outlet heater water hose connector to the stopper of the pipe.
- Connect the flow shutting valve (water by-pass hose assembly) connector.
- Connect the flow shutting valve (water by-pass hose assembly) to the water by-pass outlet sub-assembly and slide the clip to secure it.
- INSTALL INVERTER WITH CONVERTER ASSEMBLY
Refer to INSTALLATION [06/2020 - ]
- ADD ENGINE COOLANT (for Engine)
Refer to PROCEDURE - Step 2 [02/2019 - 12/2021] , or refer to PROCEDURE - Step 2 [12/2021 - ]
- INSPECT FOR COOLANT LEAK (for Engine)
Refer to PROCEDURE - Step 1