VC Output Circuit [08/2020 - ]: Description

WARNING: This page is about a different car, the 2025 Toyota RAV4, 2024 Toyota RAV4, 2023 Toyota RAV4, 2022 Toyota RAV4, and 2021 Toyota RAV4. However, it is still accessible from the selected car via links, so may be relevant.

The ECM constantly generates a 5 V power source voltage from the auxiliary battery voltage supplied to the +B, +B2 (BATT) terminals to operate the microprocessor. The ECM also provides this power to the sensors through the VC output circuit.

GTY941190Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

When the VC circuit has a short circuit, the microprocessor in the ECM and sensors that are supplied power through the VC circuit are deactivated because power is not supplied from the VC circuit. When the system is in this condition, it will not start.