Removal [10/2023 - ]: Procedure
- DRAIN ENGINE COOLANT
Refer to PROCEDURE - Step 1
- REMOVE INTAKE MANIFOLD
Refer to REMOVAL [08/2020 - ]
- REMOVE GENERATOR ASSEMBLY
- for 100 A, 130 A Type:
Refer to REMOVAL [10/2023 - ]
- for 150 A Type:
Refer to REMOVAL [10/2023 - ]
- for VALEO Made:
Refer to REMOVAL [10/2023 - ]
- for 100 A, 130 A Type:
- DISCONNECT NO. 2 RADIATOR HOSE
- REMOVE WATER INLET WITH THERMOSTAT SUB-ASSEMBLY
- Disconnect the water inlet with thermostat sub-assembly connector.
- Slide the clip and disconnect the No. 7 water by-pass hose from the water inlet with thermostat sub-assembly.NOTE:
- Do not apply force to the water inlet with thermostat sub-assembly when disconnecting the No. 7 water by-pass hose.
- Do not damage the water inlet with thermostat sub-assembly.
HINT:
When disconnecting the No. 7 water by-pass hose, slide the clip, rotate the hose and pull it straight off the pipe.
- Using an 8 mm socket wrench, remove the 2 bolts and water inlet with thermostat sub-assembly.
- Remove the gasket from the water inlet with thermostat sub-assembly.
- Disconnect the water inlet with thermostat sub-assembly connector.