Inspection [11/2018 - 02/2019]: Procedure
- INSPECT FUEL LID LOCK WITH MOTOR ASSEMBLY
- Check the operation of the fuel lid lock with motor assembly.
*a Component without harness connected
(Fuel Lid Lock with Motor Assembly)- Apply auxiliary battery voltage to the fuel lid lock with motor assembly connector, and check that the fuel lid lock with motor assembly operates smoothly as follows.
OK
Auxiliary Battery Connection Specified Condition Auxiliary battery positive (+) → Terminal 1 (B)
Auxiliary battery negative (-) → Terminal 2 (E)Open Operation If the result is not as specified, replace the fuel lid lock with motor assembly.
- Measure the shaft stroke.
Standard
Area Condition Specified Condition A Lever pulled 15.45 to 16.11 mm (0.608 to 0.634 in.) If the result is not as specified, replace the fuel lid lock with motor assembly.
- Apply auxiliary battery voltage to the fuel lid lock with motor assembly connector, and check that the fuel lid lock with motor assembly operates smoothly as follows.
- Check the operation of the fuel lid lock with motor assembly.