Home >> Toyota >> 2020 >> RAV4 LE, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 136 (Hybrid Control System (Lithium-Ion Battery) - Circuit Tests (2 Of 2)) >> HYBRID CONTROL SYSTEM (for LITHIUM-ION BATTERY) >> Generator Resolver Circuit [06/2020 - ] >> Description

Generator Resolver Circuit [06/2020 - ]: Description

WARNING: This page is about a different variant/trim than selected.

The cause of this malfunction may be the generator resolver.

Check the generator resolver internal resistance and connection condition from the inverter to the resolver.

RELATED PARTS CHECK

Area Inspection
Wire harness and connector between the inverter and generator resolver Check for short circuit between wire harness and +B side.
Resolver, wire harness, connector Check the resolver wire harness internal resistance, body ground resistance, and connector connection condition.
Resolver Check for open or short circuit of the resolver