Cooling Fan Circuit [06/2015 - ]: Procedure
- PERFORM ACTIVE TEST USING TECHSTREAM (Radiator Fan 1)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / FC / Active Test / Radiator Fan 1.
Powertrain > FC > Active Test
Tester Display Radiator Fan 1 - Check the operation of the fan while operating them using the Techstream.OK
Tester Operation Fan Operation ON Cooling fan operate OFF Cooling fan stop Result
Result Proceed to OK A NG (Fan does not operate) B NG (Fan does not stop) C
Result:
B
See step 3
Result:
C
See step 15
Result:
A
See step 2
- PERFORM ACTIVE TEST USING TECHSTREAM (Radiator Fan 2)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / FC / Active Test / Radiator Fan 2.
Powertrain > FC > Active Test
Tester Display Radiator Fan 2 - Check the operation of the fan while operating them using the Techstream.OK
Tester Operation Fan Operation ON Cooling fan operate OFF Cooling fan stop Result
Result Proceed to OK A NG (Fan does not operate) B NG (Fan does not stop) C
Result:
A
GO TO PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [06/2015 - ]
Result:
B
See step 9
Result:
C
See step 18
- CHECK HARNESS AND CONNECTOR (POWER SOURCE)
- Remove the radiator fan relay (RDI FAN NO. 1) from the motor room relay block.
*1 Motor Room Relay Block *a Radiator Fan Relay (RDI FAN NO. 1) Holder - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 3 (Radiator fan relay (RDI FAN NO. 1) holder) - Body ground Always 11 to 14V - Install the radiator fan relay (RDI FAN NO. 1) to the motor room relay block.
Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS AND CONNECTOR (RADIATOR FAN RELAY - BODY GROUND)
Result:
OK
See step 4
- Remove the radiator fan relay (RDI FAN NO. 1) from the motor room relay block.
- CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - RADIATOR FAN RELAY (RDI FAN NO. 1))
- Disconnect the A48 FC control ECU connector.
- Remove the radiator fan relay (RDI FAN NO. 1) from the motor room relay block.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A48-52 (RLFM) - 1 (Radiator fan relay (RDI FAN NO. 1)) Always Below 1 Ω A48-52 (RLFM) or 1 (Radiator fan relay (RDI FAN NO. 1)) - Other terminals or Body ground Always 10 kΩ or higher - Install the radiator fan relay (RDI FAN NO. 1) to the motor room relay block.
- Connect the A48 FC control ECU connector.
Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS AND CONNECTOR (FC CONTROL ECU - RADIATOR FAN RELAY (RDI FAN NO. 1))
Result:
OK
See step 5
- CHECK RADIATOR FAN RELAY
Refer to PROCEDURE - Step 1
Result
Proceed to OK NG Result:
NG
REPLACE RADIATOR FAN RELAY
Result:
OK
See step 6
- CHECK HARNESS AND CONNECTOR (RADIATOR FAN RELAY (RDI FAN NO. 1) - BODY GROUND)
- Remove the radiator fan relay (RDI FAN NO. 1) from the motor room relay block.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 2 (Radiator fan relay (RDI FAN NO. 1)) - Body ground Always Below 1 Ω - Install the radiator fan relay (RDI FAN NO. 1) to the motor room relay block.
Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS AND CONNECTOR (RADIATOR FAN RELAY (RDI FAN NO. 1) - BODY GROUND)
Result:
OK
See step 7
- CHECK HARNESS AND CONNECTOR (COOLING FAN WITH CONTROLLER MOTOR (for Fan Side) - RADIATOR FAN RELAY (RDI FAN NO. 1))
- Disconnect the A53 cooling fan with controller motor (for Fan Side).
- Remove the radiator fan relay (RDI FAN NO. 1) from the motor room relay block.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A53-3(+B1) - 5 (Radiator fan relay (RDI FAN NO. 1)) Always Below 1 Ω A53-3 (+B1) or 5 (Radiator fan relay (RDI FAN NO. 1)) - Other terminals or Body ground Always 10 kΩ or higher - Install the radiator fan relay (RDI FAN NO. 1) to the motor room relay block.
- Connect the A53 cooling fan with controller motor (for Fan Side).
Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS AND CONNECTOR (COOLING FAN WITH CONTROLLER MOTOR (for Fan Side) - RADIATOR FAN RELAY (RDI FAN NO. 1))
Result:
OK
See step 8
- CHECK HARNESS AND CONNECTOR (COOLING FAN WITH CONTROLLER MOTOR (for Fan Side) - BODY GROUND)
- Disconnect the A53 cooling fan with controller motor (for Fan Side).
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A53-3 (E1) - Body ground Always Below 1 Ω - Connect the A53 cooling fan with controller motor (for Fan Side).
Result
Proceed to OK NG
Result:
OK
See step 15
Result:
NG
REPAIR OR REPLACE HARNESS AND CONNECTOR (COOLING FAN WITH CONTROLLER MOTOR (for Fan Side) - BODY GROUND)
- CHECK HARNESS AND CONNECTOR (POWER SOURCE)
- Remove the No. 2 radiator fan relay (RDI FAN NO. 2) from the motor room relay block.
*1 Motor Room Relay Block *a Radiator No. 2 radiator Fan Relay (RDI FAN NO. 2) Holder - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 3 (No. 2 radiator fan relay (RDI FAN NO. 1) holder) - Body ground Always 11 to 14V - Install the No. 2 radiator fan relay (RDI FAN NO. 2) to the motor room relay block.
Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS AND CONNECTOR (RADIATOR FAN RELAY - BODY GROUND)
Result:
OK
See step 10
- Remove the No. 2 radiator fan relay (RDI FAN NO. 2) from the motor room relay block.
- CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - NO. 2 RADIATOR FAN RELAY (RDI FAN NO. 2))
- Disconnect the A48 FC control ECU connector.
- Remove the No. 2 radiator fan relay (RDI FAN NO. 2) from the motor room relay block.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A48-52 (RLFM) - 1 (No. 2 radiator fan relay (RDI FAN NO. 2)) Always Below 1 Ω A48-52 (RLFM) or 1 (No. 2 radiator fan relay (RDI FAN NO. 2)) - Other terminals or Body ground Always 10 kΩ or higher - Install the No. 2 radiator fan relay (RDI FAN NO. 2) to the motor room relay block.
- Connect the A48 FC control ECU connector.
Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS AND CONNECTOR (FC CONTROL ECU - NO. 2 RADIATOR FAN RELAY (RDI FAN NO. 2))
Result:
OK
See step 11
- CHECK NO. 2 RADIATOR FAN RELAY
Refer to PROCEDURE - Step 2
Result
Proceed to OK NG Result:
NG
REPLACE RADIATOR FAN RELAY
Result:
OK
See step 12
- CHECK HARNESS AND CONNECTOR (NO. 2 RADIATOR FAN RELAY (RDI FAN NO. 2) - BODY GROUND)
- Remove the No. 2 radiator fan relay (RDI FAN NO. 2) from the motor room relay block.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 2 (No. 2 radiator fan relay (RDI FAN NO. 2)) - Body ground Always Below 1 Ω - Install the No. 2 radiator fan relay (RDI FAN NO. 2) to the motor room relay block.
Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS AND CONNECTOR (NO. 2 RADIATOR FAN RELAY (RDI FAN NO. 2) - BODY GROUND)
Result:
OK
See step 13
- CHECK HARNESS AND CONNECTOR (COOLING FAN WITH CONTROLLER MOTOR (for No. 2 Fan Side) - NO. 2 RADIATOR FAN RELAY (RDI FAN NO. 2))
- Disconnect the A54 cooling fan with controller motor (for No. 2 Fan Side).
- Remove the No. 2 radiator fan relay (RDI FAN NO. 2) from the motor room relay block.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A54-3(+B2) - 5 (No. 2 radiator fan relay (RDI FAN NO. 2)) Always Below 1 Ω A54-3 (+B2) or 5 (No. 2 radiator fan relay (RDI FAN NO. 2)) - Other terminals or Body ground Always 10 kΩ or higher - Install the No. 2 radiator fan relay (RDI FAN NO. 2) to the motor room relay block.
- Connect the A54 cooling fan with controller motor (for No. 2 Fan Side).
Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS AND CONNECTOR (COOLING FAN WITH CONTROLLER MOTOR (for No. 2 Fan Side) - NO. 2 RADIATOR FAN RELAY (RDI FAN NO. 2))
Result:
OK
See step 14
- CHECK HARNESS AND CONNECTOR (COOLING FAN WITH CONTROLLER MOTOR (for No. 2 Fan Side) - BODY GROUND)
- Disconnect the A54 cooling fan with controller motor (for No. 2 Fan Side).
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A54-3 (E2) - Body ground Always Below 1 Ω - Connect the A54 cooling fan with controller motor (for No. 2 Fan Side).
Result
Proceed to OK NG
Result:
OK
See step 18
Result:
NG
REPAIR OR REPLACE HARNESS AND CONNECTOR (COOLING FAN WITH CONTROLLER MOTOR (for No. 2 Fan Side) - BODY GROUND)
- CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - COOLING FAN WITH CONTROLLER MOTOR (for Fan Side))
- Disconnect the A48 FC control ECU connector.
- Disconnect the A53 cooling fan with controller motor (for Fan Side).
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A48-4 (WFN1) - A53-2 (SI) Always Below 1 Ω A48-4 (WFN1) or A53-2 (SI) - Other terminals or Body ground Always 10 kΩ or higher - Connect the A53 cooling fan with controller motor (for Fan Side).
- Connect the A48 FC control ECU connector.
Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS AND CONNECTOR (FC CONTROL ECU - COOLING FAN WITH CONTROLLER MOTOR (for Fan Side))
Result:
OK
See step 16
- REPLACE COOLING FAN WITH CONTROLLER MOTOR (for Fan Side)
Refer to REMOVAL [06/2015 - 11/2018] , or refer to REMOVAL [11/2018 - ]
Result
Proceed to Next Result:
Next
See step 17
- CONFIRM PROBLEM SYMPTOMS
- Check whether the problem symptoms have been corrected.
Result
Result Proceed to Problem has been corrected. A Problem has not been corrected. B
Result:
A
END
Result:
B
REPAIR FC CONTROL ECU. Refer to REMOVAL [06/2015 - 11/2018] , or refer to REMOVAL [11/2018 - ]
- Check whether the problem symptoms have been corrected.
- CHECK HARNESS AND CONNECTOR (FC CONTROL ECU - COOLING FAN WITH CONTROLLER MOTOR (for No. 2 Fan Side))
- Disconnect the A48 FC control ECU connector.
- Disconnect the A54 cooling fan with controller motor (for No. 2 Fan Side).
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A48-12 (WFN2) - A54-2 (SI2) Always Below 1 Ω A48-12 (WFN2) or A54-2 (SI2) - Other terminals or Body ground Always 10 kΩ or higher - Connect the A54 cooling fan with controller motor (for No. 2 Fan Side).
- Connect the A48 FC control ECU connector.
Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS AND CONNECTOR (FC CONTROL ECU - COOLING FAN WITH CONTROLLER MOTOR (for No. 2 Fan Side))
Result:
OK
See step 19
- REPLACE COOLING FAN WITH CONTROLLER MOTOR (for Fan No. 2 Side)
Refer to REMOVAL [06/2015 - 11/2018] , or refer to REMOVAL [11/2018 - ]
Result
Proceed to Next Result:
Next
See step 20
- CONFIRM PROBLEM SYMPTOMS
- Check whether the problem symptoms have been corrected.
Result
Result Proceed to Problem has been corrected. A Problem has not been corrected. B
Result:
A
END
Result:
B
REPAIR FC CONTROL ECU. Refer to REMOVAL [06/2015 - 11/2018] , or refer to REMOVAL [11/2018 - ]
- Check whether the problem symptoms have been corrected.