Operating Light Control Rheostat does not Change Light Brightness [06/2015 - ]: Procedure
- READ VALUE USING TECHSTREAM (LIGHT CONTROL UP SWITCH, LIGHT CONTROL DOWN SWITCH)
- Using the Techstream, read the Data List.
Refer to DATA LIST / ACTIVE TEST [06/2015 - 01/2018] , or refer to DATA LIST / ACTIVE TEST [01/2018 - 11/2018] , or refer to DATA LIST / ACTIVE TEST [11/2018 - ]
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Light Control Up Switch Light control rheostat up switch OFF or ON OFF: Light control rheostat up switch released
ON: Light control rheostat up switch pressed- Light Control Down Switch Light control rheostat down switch OFF or ON OFF: Light control rheostat down switch released
ON: Light control rheostat down switch pressed- Body Electrical > Combination Meter > Data List
Tester Display Light Control Up Switch Light Control Down Switch OK
Light control rheostat up or down switch condition displayed on the Techstream changes with the actual switch operation.
Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [06/2015 - 11/2018] , or refer to REMOVAL [11/2018 - ]
Result:
NG
See step 2
- Using the Techstream, read the Data List.
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat.
Refer to REMOVAL [06/2015 - ]
- Inspect the light control rheostat.
Refer to INSPECTION [06/2015 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE LIGHT CONTROL RHEOSTAT. Refer to REMOVAL [06/2015 - ]
Result:
OK
See step 3
- Remove the light control rheostat.
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT)
- Disconnect the G13 combination meter assembly connector.
- Disconnect the G12 light control rheostat.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G13-24 (TR) -G12-3 (UP) Always Below 1 Ω G13-25 (TC) -G12-2 (DOWN) Always Below 1 Ω G13-24 (TR) or G12-3 (UP) - Body ground Always 10 kΩ or higher G13-25 (SW3) or G12-2 (DOWN) - Body ground Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [06/2015 - 11/2018] , or refer to REMOVAL [11/2018 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR