  1. CHANGE SUBSCRIPTION MODE 
    1. Turn the power switch on (IG).
    2. Push the manual (SOS) switch.
    3. The vehicle will issue a voice prompt: "Safety Connect is not initialized. To activate, please press the button again within 5 seconds."
    4. Push the manual (SOS) switch and a beep will be emitted.
    5. The telematics service provider will send an End Call command and the manual (SOS) switch green indicator will illuminate.
    6. A voice prompt will state: "Activation Complete." (This may take up to 3 minutes.)
    7. Turn the power switch off.

      Result

      Proceed to
      NEXT

    Result: 

    NEXT 

    See step  2

  2. CHECK SUBSCRIPTION MODE 
    1. Turn the power switch on (IG).
    2. Confirm that the manual (SOS) switch red indicator illuminates for 2 seconds and turns off and the manual (SOS) switch green indicator illuminates and remains on.

      Refer to SYSTEM DESCRIPTION [06/2015 - 01/2018]

      Result

      Proceed to
      NEXT

    Result: 

    NEXT 

    END