LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2020 >> Highlander L, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 5 (Hybrid Control System - Diagnostic Codes (5 Of 5) & Circuit Tests) >> Hybrid Control System >> DTC P321E-9F: Motor/Generator Shutdown Signal Stuck Off [11/2023 - ] >> DTC Summary

DTC Summary

WARNING: This page is about a different car, the 2025 Toyota Highlander and 2024 Toyota Highlander. However, it is still accessible from the selected car via links, so may be relevant.
  1. MALFUNCTION DESCRIPTION 

    The hybrid vehicle control ECU detects malfunctions which prevent the inverter with converter assembly emergency shutdown circuit (HSDN) from shutting down the hybrid control system. Detection is performed when the ignition switch is turned to ON and during the shutdown sequence when the ignition switch is turned off.

    The cause of this malfunction may be one of the following:

    Hybrid vehicle control ECU and inverter with converter assembly shutdown circuit malfunction 

    • Hybrid vehicle control ECU malfunction
    • Connector or wire harness malfunction (between hybrid vehicle control ECU and inverter with converter assembly) malfunction
    • Inverter with converter assembly malfunction