DTC P1CFF-62: Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure [11/2023 - ]: Procedure
WARNING: This page is about a different car, the 2025 Toyota Highlander and 2024 Toyota Highlander. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK DTC OUTPUT
Pre-procedure1
- None.
Procedure1
- Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes
Powertrain > Motor Generator > Trouble Codes
Result
Result Proceed to P1CFF-62 only is output, or DTCs except the ones in the table below are also output. A DTCs of hybrid control system in the tables below are output. B DTCs of motor generator control system in the tables below are output. C TABLE 1Malfunction Content System Relevant DTC Insulation Malfunction Hybrid control system P1C7C-49 Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure P1C7D-49 Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure P1C7E-49 Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure P1C7F-49 Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure P1C80-49 Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure HV Battery Malfunction Hybrid control system P0ABF-00 Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance P0ABF-11 Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground P0ABF-15 Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open P0ABF-28 Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure P0ABF-2A Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range P0AFC-00 Hybrid/EV Battery Sensor Module P0AFC-16 Hybrid/EV Battery Sensor Module Circuit Voltage Below Threshold P0AFC-62 Hybrid/EV Battery Sensor Module Signal Compare Failure P0AFC-96 Hybrid/EV Battery Sensor Module Component Internal Failure P1CBB-12 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery P1CBB-14 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open U029A-87 Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message TABLE 2Malfunction Content System Relevant DTC Microcomputer malfunction Motor generator control system P0A1A-47 Generator Control Module Watchdog / Safety MC Failure P0A1A-49 Generator Control Module Internal Electronic Failure P0A1B-1F Generator Control Module Circuit Intermittent P1C2A-1C Generator A/D Converter Circuit Circuit Voltage Out of Range P1C2A-49 Generator A/D Converter Circuit Internal Electronic Failure P1C2B-1C Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range P1C2B-49 Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure P3133-83 Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect P3133-86 Communication Error from Generator to Drive Motor "A" Signal Invalid P3133-87 Communication Error from Generator to Drive Motor "A" Missing Message P3134-83 Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect P3134-86 Communication Error from Drive Motor "A" to Generator Signal Invalid P3134-87 Communication Error from Drive Motor "A" to Generator Missing Message Hybrid control system P0A1B-49 Drive Motor "A" Control Module Internal Electronic Failure Power source circuit malfunction Motor generator control system P06B0-1C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range P06D6-1C Generator Control Module Offset Power Circuit Voltage Out of Range P262C-1C Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range Communication malfunction Motor generator control system P3124-87 Lost Communication between Drive Motor "A" and HV/EV ECU Missing Message Hybrid control system P3123-87 Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message Sensor and actuator circuit malfunction Motor generator control system P0E51-11 DC/DC Converter Current Sensor Circuit Short to Ground P0E51-15 DC/DC Converter Current Sensor Circuit Short to Battery or Open P0E51-28 DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure HINT:
- P1CFF-62 may be output as a result of the malfunction indicated by the DTCs above.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
- P1CFF-62 may be output as a result of the malfunction indicated by the DTCs above.
- Turn the ignition switch off.
Result:
B
GO TO DTC CHART (HYBRID CONTROL SYSTEM)
Refer to DIAGNOSTIC TROUBLE CODE CHART [11/2023 - ]
Result:
C
GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM). Refer to DIAGNOSTIC TROUBLE CODE CHART [11/2023 - ]
Result:
A
See step 2
- None.
- CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Refer to PROCEDURE - Step 3
Result
Result Proceed to OK A NG (The connector is not connected securely.) B NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C Result:
A
REPLACE INVERTER WITH CONVERTER ASSEMBLY
Refer to REMOVAL [11/2023 - ]
Result:
B
CONNECT SECURELY
Result:
C
REPAIR OR REPLACE HARNESS OR CONNECTOR