DTC P0504-2B: Brake Switch "A"/"B" Signal Cross Coupled [06/2018 - 01/2019]: Procedure
- CHECK TERMINAL VOLTAGE (STOP LIGHT SWITCH ASSEMBLY)
*a Front view of wire harness connector
(to Stop Light Switch Assembly)- Disconnect the stop light switch assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition A53-7 (B) - Body ground Always 11 to 14 V Result
Proceed to OK NG
Result:
NG
See step 10
Result:
OK
See step 2
- CHECK TERMINAL VOLTAGE (STOP LIGHT SWITCH ASSEMBLY)
*a Front view of wire harness connector
(to Stop Light Switch Assembly)- Disconnect the stop light switch assembly connector.
- Turn the engine switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition A53-6 (B) - Body ground Engine switch on (IG) 11 to 14 V Result
Proceed to OK NG
Result:
NG
See step 6
Result:
OK
See step 3
- CHECK HARNESS AND CONNECTOR (STOP LIGHT SWITCH ASSEMBLY - BODY GROUND)
- Disconnect the stop light switch assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A53-2 (GND) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- CHECK TERMINAL VOLTAGE (ECM)
*a Brake Pedal Depressed *b Brake Pedal Released *c Front view of wire harness connector
(to ECM)- - - Disconnect the ECM connector.
- Turn the engine switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Brake Pedal Operation Specified Condition A47-22 (ST1-) - Body ground Released 7.5 to 14 V Depressed Below 1.5 V A47-21 (STP) - Body ground Released Below 1.5 V Depressed 7.5 to 14 V Result
Proceed to OK NG
Result:
OK
REPLACE ECM
Refer to REMOVAL [06/2018 - 01/2019]
Result:
NG
See step 5
- CHECK HARNESS AND CONNECTOR (STOP LIGHT SWITCH ASSEMBLY - ECM)
- Disconnect the stop light switch assembly connector.
- Disconnect the ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A53-5 (L) - A47-22 (ST1-) Always Below 1 Ω A53-3 (L) - A47-21 (STP) Always Below 1 Ω A53-5 (L) or A47-22 (ST1-) - Body ground and other terminals Always 10 kΩ or higher A53-3 (L) or A47-21 (STP) - Body ground and other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE STOP LIGHT SWITCH ASSEMBLY
Refer to REMOVAL [06/2018 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - STOP LIGHT SWITCH ASSEMBLY)
- Disconnect the instrument panel junction block assembly connector.
- Disconnect the stop light switch assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 4B-15 - A53-6 (B) Always Below 1 Ω 4B-15 or A53-6 (B) - Body ground and other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 7
- CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - BODY GROUND)
- Disconnect the instrument panel junction block assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 4F-3 - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 8
- CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - CERTIFICATION ECU (SMART KEY ECU ASSEMBLY))
- Disconnect the instrument panel junction block assembly connector.
- Disconnect the certification ECU (smart key ECU assembly) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 4E-17 - I1-15 (IG1D) Always Below 1 Ω 4E-17 or I1-15 (IG1D) - Body ground and other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 9
- CHECK SMART KEY SYSTEM
- Check the smart key system.
Refer to HOW TO PROCEED WITH TROUBLESHOOTING [06/2018 - 01/2019]
Result
Proceed to OK NG
Result:
OK
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Refer to REMOVAL [06/2018 - 01/2019]
Result:
NG
REPAIR SMART KEY SYSTEM
Refer to HOW TO PROCEED WITH TROUBLESHOOTING [06/2018 - 01/2019]
- Check the smart key system.
- CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - STOP LIGHT SWITCH ASSEMBLY)
- Disconnect the instrument panel junction block assembly connector.
- Disconnect the stop light switch assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 4B-3 - A53-7 (B) Always Below 1 Ω 4B-3 or A53-7 (B) - Body ground and other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 11
- CHECK TERMINAL VOLTAGE (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
*a Front view of wire harness connector
(to Instrument Panel Junction Block Assembly)- Disconnect the instrument panel junction block assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 4C-1 - Body ground Always 11 to 14 V Result
Proceed to OK NG
Result:
OK
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Refer to REMOVAL [06/2018 - 01/2019]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)